ASTM C1697 Standard Specification for Blended Supplementary Cementitious Materials
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM D7380 Standard Test Method for Soil Compaction Determination at Shallow Depths Using 5-lb (2.3 kg) Dynamic Cone Penetrometer
- 13
- ASTM D7380 Standard Test Method for Soil Compaction Determination at Shallow Depths Using 5-lb (2.3 kg) Dynamic Cone Penetrometer
- 13.080
- ASTM D7380 Standard Test Method for Soil Compaction Determination at Shallow Depths Using 5-lb (2.3 kg) Dynamic Cone Penetrometer
- 13.080.20
- 93
- ASTM D7380 Standard Test Method for Soil Compaction Determination at Shallow Depths Using 5-lb (2.3 kg) Dynamic Cone Penetrometer
- 93.020
- ASTM D1557 Standard Test Methods for Laboratory Compaction Characteristics of Soil Using Modified Effort (56,000 ft-lbf/ft3 (2,700 kN-m/m3))
- ASTM C1245/C1245M Standard Test Method for Determining Relative Bond Strength Between Hardened Roller Compacted Concrete Lifts (Point Load Test)
- ASTM C125 REV B Standard Terminology Relating to Concrete and Concrete Aggregates
- Картотека зарубежных и международных стандартов
ASTM International
Standard Specification for Blended Supplementary Cementitious Materials
N C1697
Annotation
This specification covers blended supplementary cementitious materials that result from the blending or intergrinding of two or three ASTM compliant supplementary cementitious materials, for use in concrete or mortar where hydraulic or pozzolanic action, or both, is desired. The supplementary cementitious materials include slag cement conforming to Specification C989/C989M, natural pozzolans and coal fly ash conforming to Specification C618 and silica fume conforming to Specification C1240.
The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
NOTE 1—The incorporation of supplementary cementitious materials as separate additions or as a manufactured blend may significantly alter the properties of fresh and hardened concrete. The user should be aware of these changes and is referred to the ACI Manual of Concrete Practice2 for information and guidelines. Specific reference is made to:
2 Available from American Concrete Institute (ACI), P.O. Box 9094, Farmington Hills, MI 48333-9094, http://www.concrete.org.
ACI 232.1R Use of Natural Pozzolans in Concrete
ACI 232.2R Use of Fly Ash in Concrete
ACI 233R Slag Cement in Concrete and Mortar
ACI 234R Guide for the Use of Silica Fume in Concrete
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.