DIN EN 62722-2-1 Luminaire performance - Part 2-1: Particular requirements for LED luminaires (IEC 62722-2-1:2014, modified)
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- CSA CAN/CSA-C22.2 NO. 61010-031-07 Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test - First Edition
- 19
- CSA CAN/CSA-C22.2 NO. 61010-031-07 Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test - First Edition
- 19.080
- CSA CAN/CSA-C22.2 NO. 61010-031-07 Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test - First Edition
- IEC 60529 CORR 3 Degrees of Protection Provided by Enclosures (IP Code) - Edition 2.1
- CSA CAN/CSA-C22.2 NO. 61010-031-07 AMD 1 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test - First Edition
- 13
- IEC 60529 CORR 3 Degrees of Protection Provided by Enclosures (IP Code) - Edition 2.1
- CSA CAN/CSA-C22.2 NO. 61010-031-07 AMD 1 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test - First Edition
- 13.260
- IEC 60529 CORR 3 Degrees of Protection Provided by Enclosures (IP Code) - Edition 2.1
- CSA CAN/CSA-C22.2 NO. 61010-031-07 AMD 1 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test - First Edition
- IEC 60529 CORR 3 Degrees of Protection Provided by Enclosures (IP Code) - Edition 2.1
- IEC 60529 CORR 3 Degrees of Protection Provided by Enclosures (IP Code) - Edition 2.1
- 29
- IEC 60529 CORR 3 Degrees of Protection Provided by Enclosures (IP Code) - Edition 2.1
- CSA CAN/CSA-C22.2 NO. 61010-031-07 AMD 1 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test - First Edition
- IEC 60529 CORR 3 Degrees of Protection Provided by Enclosures (IP Code) - Edition 2.1
- CSA CAN/CSA-C22.2 NO. 61010-031-07 AMD 1 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test - First Edition
- CENELEC EN 62146-1 Grading capacitors for high-voltage alternating current circuit-breakers - Part 1: General - Incorporates Amendment A1: 2016
- IEC 60050-614 International electrotechnical vocabulary – Part 614: Generation, transmission and distribution of electricity – Operation - Edition 1.0
- Картотека зарубежных и международных стандартов
Deutsches Institut fur Normung e. V.
Luminaire performance - Part 2-1: Particular requirements for LED luminaires (IEC 62722-2-1:2014, modified)
N EN 62722-2-1
Annotation
Dieser Teil der IEC 62722 legt die Anforderungen an LED-Leuchten und Prufverfahren fest, sowie Bedingungen, die erforderlich sind, um die Ubereinstimmung mit dieser Norm nachzuweisen. Sie gilt fur LEDLeuchten fur die Verwendung in der Allgemeinbeleuchtung.
Die folgenden Typen von LED-Leuchten werden unterschieden:
– Typ A – Leuchten, in denen LED-Module verwendet werden, die mit IEC 627171) N1) ubereinstimmen;
– Typ B – Leuchten, in denen LED-Module verwendet werden, die nicht mit IEC 627171) N1) ubereinstimmen;
– Typ C – Leuchten, in denen LED-Lampen verwendet werden und die in IEC 62722-1 beschrieben sind.
Die Anforderungen dieser Norm beziehen sich nur auf die Typprufung.
Diese Norm gilt nicht fur Typ C-Leuchten.
Diese Norm gilt nicht fur LED-Leuchten, die absichtlich farbiges Licht erzeugen, und auch nicht fur Leuchten, in denen OLEDs (organische LEDs) eingesetzt sind.
Diese Anforderungen an die Arbeitsweise gelten zusatzlich zu den Anforderungen nach IEC 62722-1, Abschnitte 1 bis 9, au?er dieser Teil 2-1 legt alternative Messverfahren oder Grenzwerte fest.
Da diese Norm zeitgleich mit der Norm fur LED-Module entwickelt und bearbeitet wurde, kann die Ubereinstimmung der Module nach IEC 62717 gegebenenfalls auf die gesamte Leuchte ubertragen werden.
Die Lebensdauer von LED-Leuchten ist in den meisten Fallen viel langer als die angesetzten Prufzeiten. Infolgedessen kann der Nachweis der Lebensdauerangaben des Herstellers nicht in ausreichend uberzeugender Weise erbracht werden. Daher ist die Annahme oder die Abweisung einer Lebensdauerangabe des Herstellers, nach 25 % der Bemessungslebensdauer (mit einem Hochstwert von 6 000 h), nicht durch den Anwendungsbereich dieser Norm abgedeckt.



