CEN EN 14792 Stationary source emissions - Determination of mass concentration of nitrogen oxides - Standard reference method: chemiluminescence
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- DS DS/EN 14181 Stationary source emissions - Quality assurance of automated measuring systems
- 13
- ASTM D7859 Standard Practice for Spraying, Sampling, Packaging, and Test Specimen Preparation of Spray Polyurethane Foam (SPF) Insulation for Testing of Emissions Using Environmental Chambers
- ASTM D7706 Standard Practice for Rapid Screening of VOC Emissions from Products Using Micro-Scale Chambers
- ASTM D5197 Standard Test Method for Determination of Formaldehyde and Other Carbonyl Compounds in Air (Active Sampler Methodology)
- ISO 10580 Resilient, textile and laminate floor coverings — Test method for volatile organic compound (VOC) emissions - First Edition
- ASTM D5197 Standard Test Method for Determination of Formaldehyde and Other Carbonyl Compounds in Air (Active Sampler Methodology)
- ASTM D7706 Standard Practice for Rapid Screening of VOC Emissions from Products Using Micro-Scale Chambers
- ASTM D7706 Standard Practice for Rapid Screening of VOC Emissions from Products Using Micro-Scale Chambers
- ASTM D5197 Standard Test Method for Determination of Formaldehyde and Other Carbonyl Compounds in Air (Active Sampler Methodology)
- ISO 10580 Resilient, textile and laminate floor coverings — Test method for volatile organic compound (VOC) emissions - First Edition
- ASTM D5197 Standard Test Method for Determination of Formaldehyde and Other Carbonyl Compounds in Air (Active Sampler Methodology)
- ASTM D5197 Standard Test Method for Determination of Formaldehyde and Other Carbonyl Compounds in Air (Active Sampler Methodology)
- ISO 10580 Resilient, textile and laminate floor coverings — Test method for volatile organic compound (VOC) emissions - First Edition
- ISO 10580 Resilient, textile and laminate floor coverings — Test method for volatile organic compound (VOC) emissions - First Edition
- ASTM D7339 Standard Test Method for Determination of Volatile Organic Compounds Emitted from Carpet using a Specific Sorbent Tube and Thermal Desorption / Gas Chromatography
- ASTM D6196 Standard Practice for Selection of Sorbents, Sampling, and Thermal Desorption Analysis Procedures for Volatile Organic Compounds in Air
- CEN EN 16738 Emission safety of combustible air fresheners - Test methods
- Картотека зарубежных и международных стандартов
European Committee for Standardization
Stationary source emissions - Determination of mass concentration of nitrogen oxides - Standard reference method: chemiluminescence
N EN 14792
Annotation
This European Standard specifies the standard reference method (SRM) based on the chemiluminescence principle for the determination of the nitrogen oxides (NOx) in flue gases emitted to the atmosphere from ducts and stacks. It includes the sampling and the gas conditioning system, as well as the analyser.
This European Standard specifies the characteristics to be determined and the performance criteria to be fulfilled by portable automated measuring systems (P-AMS) based on this measurement method. It applies for periodic monitoring and for the calibration or control of automated measuring systems (AMS) permanently installed on a stack, for regulatory or other purposes.
This European Standard specifies criteria for demonstration of equivalence of an alternative method to the SRM by application of EN 14793:2017. This European Standard has been validated during field tests on waste incineration, co-incineration and large combustion installations and on a recognized test-bench. It has been validated for sampling periods of 30 min in the range of 0 mg/m3 to 1 300 mg/m3 of NOx for large combustion plants and 0 mg/m3 to 400 mg/m3 of NOx for waste incineration, according to emission limit values (ELV) laid down in the Directive 2010/75/EU.
The ELV for NOx (NO + NO2) in EU Directives is expressed in mg/m3 of NO2 on a dry basis, at a specified value for oxygen and at standard conditions (273 K and 101,3 kPa).
NOTE The characteristics of installations, the conditions during field tests and the values of repeatability and reproducibility in the field are given in Annex A.