CENELEC EN 50583-2 Photovoltaics in buildings - Part 2: BIPV systems
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- CENELEC CLC/TR 62685 Industrial communication networks - Profiles - Assessment guideline for safety devices using IEC 61784-3 functional safety communication profiles (FSCPs)
- 13
- CENELEC CLC/TR 62685 Industrial communication networks - Profiles - Assessment guideline for safety devices using IEC 61784-3 functional safety communication profiles (FSCPs)
- 13.160
- CENELEC CLC/TR 62685 Industrial communication networks - Profiles - Assessment guideline for safety devices using IEC 61784-3 functional safety communication profiles (FSCPs)
- 35
- CENELEC CLC/TR 62685 Industrial communication networks - Profiles - Assessment guideline for safety devices using IEC 61784-3 functional safety communication profiles (FSCPs)
- 35.100
- CENELEC CLC/TR 62685 Industrial communication networks - Profiles - Assessment guideline for safety devices using IEC 61784-3 functional safety communication profiles (FSCPs)
- 35.100.05
- CENELEC CLC/TR 62685 Industrial communication networks - Profiles - Assessment guideline for safety devices using IEC 61784-3 functional safety communication profiles (FSCPs)
- IEC 61326-3-1 CORR 1 Electrical equipment for measurement, control and laboratory use – EMC requirements – Part 3-1: Immunity requirements for safety-related systems and for equipment intended to perform safety-related functions (functional safety) – General industrial applications CORRIGENDUM1 - Edition 1.0
- CENELEC CLC/TR 62685 Industrial communication networks - Profiles - Assessment guideline for safety devices using IEC 61784-3 functional safety communication profiles (FSCPs)
- IEC 62446-1 Photovoltaic (PV) systems – Requirements for testing, documentation and maintenance – Part 1: Grid connected systems – Documentation, commissioning tests and inspection - Edition 1.0
- Картотека зарубежных и международных стандартов
European Committee for Electrotechnical Standardization
Photovoltaics in buildings - Part 2: BIPV systems
N EN 50583-2
Annotation
This document applies to photovoltaic systems that are integrated into buildings with the photovoltaic modules used as construction products. It focuses on the properties of these photovoltaic systems relevant to essential building requirements as specified in the European Construction Product Regulation CPR 89/106/EEC, and the applicable electro-technical requirements as stated in the Low Voltage Directive 2006/95/EC / or CENELEC standards. This document references international standards, technical reports and guidelines. For some applications in addition national standards (or regulations) for building works may apply in individual countries, which are not explicitly referenced here.
The document is addressed to manufacturers, planners, system designers, installers, testing institutes and building authorities.
This document does not apply to concentrating or building-attached photovoltaic systems.1
This document addresses requirements on the BIPV systems in the specific ways they are intended to be mounted but not the BIPV modules as construction products, which is the topic of EN 50583-1.
1 For the definition building-attached photovoltaic systems refer to 3.2
Автоматический перевод:
Гелиотехника в зданиях - Часть 2: системы BIPV
Этот документ относится к фотогальваническим системам, которые интегрированы в здания с фотогальваническими модулями, используемыми в качестве строительных продуктов. Это сосредотачивает на свойствах этих фотогальванических систем, относящихся к существенным строительным требованиям, как определено в европейском Строительном Регулировании продукта CPR 89/106/EEC и применимые электротехнические требования, как указано в Низковольтной Директиве 2006/95/EC / или стандарты CENELEC. Этот документ справочные международные стандарты, технические отчеты и инструкции. Для некоторых заявлений, кроме того, национальные стандарты (или инструкции) для строительных работ могут применяться в отдельных странах, на которые явно не ссылаются здесь.