CENELEC EN 61829 Photovoltaic (PV) array - On-site measurement of currentvoltage characteristics
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- 27
- IEC TR 62461 Radiation protection instrumentation – Determination of uncertainty in measurement - Edition 1.0
- 13
- IEC TR 62461 Radiation protection instrumentation – Determination of uncertainty in measurement - Edition 1.0
- 13.280
- IEC TR 62461 Radiation protection instrumentation – Determination of uncertainty in measurement - Edition 1.0
- CEI EN 62387-1 Radiation protection instrumentation - Passive integrating dosimetry systems for environmental and personal monitoring Part 1: General characteristics and performance requirements
- CEI EN 62387-1 Radiation protection instrumentation - Passive integrating dosimetry systems for environmental and personal monitoring Part 1: General characteristics and performance requirements
- IEC 60904-3 Photovoltaic devices – Part 3: Measurement principles for terrestrial photovoltaic (PV) solar devices with reference spectral irradiance data - Edition 2.0
- Картотека зарубежных и международных стандартов
European Committee for Electrotechnical Standardization
Photovoltaic (PV) array - On-site measurement of currentvoltage characteristics
N EN 61829
Annotation
This International Standard specifies procedures for on-site measurement of flat-plate photovoltaic (PV) array characteristics, the accompanying meteorological conditions, and use of these for translating to standard test conditions (STC) or other selected conditions.
Measurements of PV array current-voltage (I-V) characteristics under actual on-site conditions and their translation to reference test conditions (RTC) can provide:
• data for power rating or capacity testing;
• verification of installed array power performance relative to design specifications;
• detection of possible differences between on-site module characteristics and laboratory or factory measurements;
• detection of possible performance degradation of modules and arrays with respect to onsite initial data;
• detection of possible module or array failures or poor performance.
For a particular module, on-site measurements translated to STC can be directly compared with results previously obtained in a laboratory or factory for that module. Corrections for differences in the spectral or spatial response of the reference devices may need to be assessed as specified in IEC 60904.
On-site array measurements are affected by diode, cable, and mismatch losses, soiling and shading, degradation due to aging, and other uncontrolled effects. Therefore, they are not expected to be equal to the product of the number of modules and the respective module data.