CENELEC EN 60965 Nuclear power plants - Control rooms - Supplementary control room for reactor shutdown without access to the main control room
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- IEC 61513 Nuclear Power Plants - Instrumentation and Control for Systems Important to Safety - General Requirements for Systems - Edition 1.0
- 27
- IEC 61513 Nuclear Power Plants - Instrumentation and Control for Systems Important to Safety - General Requirements for Systems - Edition 1.0
- 27.120
- IEC 61513 Nuclear Power Plants - Instrumentation and Control for Systems Important to Safety - General Requirements for Systems - Edition 1.0
- 27.120.20
- BSI BS IEC 62646 Nuclear power plants - Control rooms - Computer-based procedures
- BSI BS IEC 62646 Nuclear power plants - Control rooms - Computer-based procedures
- BSI BS IEC 62646 Nuclear power plants - Control rooms - Computer-based procedures
- IEC 60965 Nuclear power plants – Control rooms – Supplementary control room for reactor shutdown without access to the main control room - Edition 3.0
- IEC 62646 Nuclear power plants – Control rooms – Computer based procedures - Edition 2.0
- Картотека зарубежных и международных стандартов
European Committee for Electrotechnical Standardization
Nuclear power plants - Control rooms - Supplementary control room for reactor shutdown without access to the main control room
N EN 60965
Annotation
This International Standard establishes requirements for the Supplementary Control Room provided to enable the operating staff of nuclear power plants to shut down the reactor, where previously operating, and maintain the plant in a safe shut-down state in the event that control of the safety functions can no longer be exercised from the Main Control Room, due to unavailability of the Main Control Room or its facilities. The design has to ensure that the Supplementary Control Room is protected against the hazards, including any localised extreme hazards, leading to the unavailability of the Main Control Room
The standard also establishes requirements for the selection of functions, the design and organisation of the human-machine interface, and the procedures which shall be used systematically to verify and validate the functional design of the supplementary control room
It is assumed that supplementary control room provided for shutdown operations from outside the main control room would be unattended during normal plant conditions other than for periodic testing. The requirements reflect the application of human engineering principles as they apply to the human-machine interface during such periodic testing and during abnormal plant conditions.
This standard does not cover special emergency response facilities (e.g. a technical support centre) or facilities provided for radioactive waste handling. Detailed equipment design is also outside the scope of the standard.
This standard follows the principles of IAEA Specific Safety Requirements SSR-2/1 and IAEA Safety Guide NS-G-1.3.