ASTM D7279 Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids by Automated Houillon Viscometer
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM D5900 Standard Specification for Physical and Chemical Properties of Industry Reference Materials (IRM)
- 19
- 83
- BSI BS EN 62535 Insulating liquids - Test method for detection of potentially corrosive sulphur in used and unused insulating oil - CORR: February 28, 2011
- DIN 51353 Testing of insulating oils; detection of corrosive sulfur; silber strip test
- CEI EN 60296 Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear
- DIN 51353 Testing of insulating oils; detection of corrosive sulfur; silber strip test
- DIN 51353 Testing of insulating oils; detection of corrosive sulfur; silber strip test
- CEI EN 60296 Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear
- CEI EN 60296 Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear
- ASTM D7150 Standard Test Method for the Determination of Gassing Characteristics of Insulating Liquids Under Thermal Stress
- ASTM D3612 Standard Test Method for Analysis of Gases Dissolved in Electrical Insulating Oil by Gas Chromatography
- ASTM D2140 Standard Practice for Calculating Carbon-Type Composition of Insulating Oils of Petroleum Origin
- Картотека зарубежных и международных стандартов
ASTM International
Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids by Automated Houillon Viscometer
N D7279
Annotation
This test method covers the measurement of the kinematic viscosity of transparent and opaque liquids; such as base oils, formulated oils, diesel oil, biodiesel, biodiesel blends, residual fuel oils, marine fuels, and used lubricating oils using a Houillon viscometer in automated mode.
The range of kinematic viscosity capable of being measured by this test method is from 2 mm2/s to 2500 mm2/s (see Fig. 1). The range is dependent on the tube constant utilized. The temperature range that the apparatus is capable of achieving is between 20 °C and 150 °C, inclusive. However, the precision has only been determined for the viscosity range; 2 mm2/s to 478 mm2/s at 40 °C for base oils, formulated oils, diesel oil, biodiesel, and biodiesel blends; 3 mm2/s to 106 mm2/s at 100 °C for base oils and formulated oils; 25 mm2/s to 150 mm2/s at 40 °C and 5 mm2/s to 16 mm2/s at 100 °C for used lubricating oils; 25 mm2/s to 2500 mm2/s at 50 °C and 6 mm2/s to 110 mm2/s at 100 °C for residual fuels. As indicated for the materials listed in the precision section.
The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see Section 6.
*A Summary of Changes section appears at the end of this standard