CEN EN ISO 15009 Soil quality - Gas chromatographic determination of the content of volatile aromatic hydrocarbons, naphthalene and volatile halogenated hydrocarbons - Purge-and-trap method with thermal desorption
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- DIN 3016-3 Fastening clamps - Part 3: Section clamps and flange dimensions
- 21
- DIN 3016-3 Fastening clamps - Part 3: Section clamps and flange dimensions
- 21.060
- DIN 3016-3 Fastening clamps - Part 3: Section clamps and flange dimensions
- 21.060.70
- DIN 3016-3 Fastening clamps - Part 3: Section clamps and flange dimensions
- DIN 3016-4 Fastening clamps - Part 4: Technical delivery conditions
- DIN 3016-1 Fastening clamps - Part 1: With tongue
- DIN 4000-44 Tabular layout of article characteristics - Part 44: Clamps
- DIN 1593 Heavy pipe clips with pipe-tightening; double-ended for rail vehicles
- DIN ISO 7168-1 Air quality - Exchange of data - Part 1: General data format (ISO 7168-1:1999)
- DIN EN ISO 28258 Soil quality - Digital exchange of soil-related data (ISO 28258:2013)
- ISO 10381-1 Soil quality - Sampling - Part 1: Guidance in the design of sampling programs - First edition
- Картотека зарубежных и международных стандартов
European Committee for Standardization
Soil quality - Gas chromatographic determination of the content of volatile aromatic hydrocarbons, naphthalene and volatile halogenated hydrocarbons - Purge-and-trap method with thermal desorption
N EN ISO 15009
Annotation
This International Standard specifies a method for quantitative gas-chromatographic determination of volatile aromatic hydrocarbons, naphthalene and volatile halogenated hydrocarbons in soil.
This International Standard is applicable to all types of soil.
NOTE In the case of unsaturated peaty soils, absorption of the extraction solution may occur.
The lower limit of quantification is dependent on the equipment used and the quality of the methanol grade used for the extraction of the soil sample.
Under the conditions specified in this International Standard the following limits of quantification apply (expressed on basis of dry matter):
Typical limit of quantification when using GC-FID:
— Volatile aromatic hydrocarbons: 0,1 mg/kg
Typical limit of quantification when using GC-ECD:
— Volatile halogenated hydrocarbons: 0,01 mg/kg
Lower limits of quantification for some compounds can be achieved by using mass spectrometry (MS) with selected ion detection.