CENELEC EN 60601-2-23 Medical electrical equipment - Part 2-23: Particular requirements for the basic safety and essential performance of transcutaneous partial pressure monitoring equipment
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- IEC 60335-1 Household and similar electrical appliances . Safety . Part 1: General requirements - Edition 5.1 Consolidated Reprint
- 13
- IEC 60335-1 Household and similar electrical appliances . Safety . Part 1: General requirements - Edition 5.1 Consolidated Reprint
- 13.120
- IEC 60335-1 Household and similar electrical appliances . Safety . Part 1: General requirements - Edition 5.1 Consolidated Reprint
- IEC TS 60479-1 CORR 1 Effects of current on human beings and livestock – Part 1: General aspects CORRIGENDUM 1 - Edition 4.0
- IEC TR 60479-4 Effects of current on human beings and livestock – Part 4: Effects of lightning strokes - Edition 2.0
- IEC TS 60479-1 CORR 2 Effects of current on human beings and livestock – Part 1: General aspects CORRIGENDUM 2 - Edition 4.0
- IEC TR 60479-4 Effects of current on human beings and livestock – Part 4: Effects of lightning strokes - Edition 2.0
- 97
- IEC 60335-1 Household and similar electrical appliances . Safety . Part 1: General requirements - Edition 5.1 Consolidated Reprint
- 97.030
- IEC 60335-1 Household and similar electrical appliances . Safety . Part 1: General requirements - Edition 5.1 Consolidated Reprint
- IEC TS 60479-1 CORR 1 Effects of current on human beings and livestock – Part 1: General aspects CORRIGENDUM 1 - Edition 4.0
- IEC TR 60479-4 Effects of current on human beings and livestock – Part 4: Effects of lightning strokes - Edition 2.0
- IEC TS 60479-1 CORR 2 Effects of current on human beings and livestock – Part 1: General aspects CORRIGENDUM 2 - Edition 4.0
- IEC TR 60479-4 Effects of current on human beings and livestock – Part 4: Effects of lightning strokes - Edition 2.0
- IEC TR 60479-4 Effects of current on human beings and livestock – Part 4: Effects of lightning strokes - Edition 2.0
- IEC TS 60479-1 CORR 2 Effects of current on human beings and livestock – Part 1: General aspects CORRIGENDUM 2 - Edition 4.0
- IEC TS 60479-1 CORR 2 Effects of current on human beings and livestock – Part 1: General aspects CORRIGENDUM 2 - Edition 4.0
- IEC 60601-2-2 CORR 1 Medical electrical equipment – Part 2-2: Particular requirements for the basic safety and essential performance of high frequency surgical equipment and high frequency surgical accessories - Edition 5.0
- CENELEC EN 60601-2-49 Medical electrical equipment - Part 2-49: Particular requirements for the basic safety and essential performance of multifunction patient monitoring equipment
- Картотека зарубежных и международных стандартов
European Committee for Electrotechnical Standardization
Medical electrical equipment - Part 2-23: Particular requirements for the basic safety and essential performance of transcutaneous partial pressure monitoring equipment
N EN 60601-2-23
Annotation
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of TRANSCUTANEOUS PARTIAL PRESSURE MONITORING EQUIPMENT as defined in 201.3.63 and hereinafter referred to as ME EQUIPMENT, whether this ME EQUIPMENT is stand alone or part of a system.
This standard applies to transcutaneous monitors used with adults, children and neonates, and it includes the use of these devices in foetal monitoring during birth.
This standard does not apply to haemoglobin saturation oximeters or to devices applied to surfaces of the body other than the skin (for example conjunctiva, mucosa).
If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant.
HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this standard are not covered by specific requirements in this standard except in 7.2.13 and 8.4.1 of the general standard.
NOTE See also 4.2 of the General Standard.
Автоматический перевод:
Медицинское электрооборудование - Часть 2-23: Конкретные требования для основной безопасности и существенной производительности чрескожного контрольного оборудования парциального давления