CEN CEN/TS 16835-2 Molecular in vitro diagnostic examinations - Specifications for pre-examination processes for venous whole blood Part 2: Isolated genomic DNA
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- 11
- CEN EN 16348 Gas infrastructure - Safety Management System (SMS) for gas transmission infrastructure and Pipeline Integrity Management System (PIMS) for gas transmission pipelines - Functional requirements
- CEN EN ISO 14001 Environmental management systems - Requirements with guidance for use
- SNV SN EN 16348 Gas infrastructure - Safety Management System (SMS) for gas transmission infrastructure and Pipeline Integrity Management System (PIMS) for gas transmission pipelines - Functional requirements
- CEN EN ISO 14001 Environmental management systems - Requirements with guidance for use
- 23
- CEN EN 16348 Gas infrastructure - Safety Management System (SMS) for gas transmission infrastructure and Pipeline Integrity Management System (PIMS) for gas transmission pipelines - Functional requirements
- CEN EN ISO 14001 Environmental management systems - Requirements with guidance for use
- SNV SN EN 16348 Gas infrastructure - Safety Management System (SMS) for gas transmission infrastructure and Pipeline Integrity Management System (PIMS) for gas transmission pipelines - Functional requirements
- CEN EN ISO 14001 Environmental management systems - Requirements with guidance for use
- CEN EN 16348 Gas infrastructure - Safety Management System (SMS) for gas transmission infrastructure and Pipeline Integrity Management System (PIMS) for gas transmission pipelines - Functional requirements
- CEN EN ISO 14001 Environmental management systems - Requirements with guidance for use
- SNV SN EN 16348 Gas infrastructure - Safety Management System (SMS) for gas transmission infrastructure and Pipeline Integrity Management System (PIMS) for gas transmission pipelines - Functional requirements
- SNV SN EN 16348 Gas infrastructure - Safety Management System (SMS) for gas transmission infrastructure and Pipeline Integrity Management System (PIMS) for gas transmission pipelines - Functional requirements
- ISO 14001 CORR 1 Environmental management systems — Requirements with guidance for use — TECHNICAL CORRIGENDUM 1 - Deuxieme Edition
- IEC TR 62476 Guidance for evaluation of products with respect to substance-use restrictions in electrical and electronic products - Edition 1.0
- IEC 62321 Electrotechnical products – Determination of levels of six regulated substances (lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, polybrominated diphenyl ethers) - Edition 1.0
- ISO GUIDE 30 Reference materials - Selected terms and definitions - Third Edition
- Картотека зарубежных и международных стандартов
European Committee for Standardization
Molecular in vitro diagnostic examinations - Specifications for pre-examination processes for venous whole blood Part 2: Isolated genomic DNA
N CEN/TS 16835-2
Annotation
This Technical Specification recommends the handling, documentation and processing of venous whole blood specimens intended for genomic DNA analysis during the preanalytical phase before a molecular assay is performed. This Technical Specification covers specimens collected by venous whole blood collection tubes. This Technical Specification is applicable to molecular in vitro diagnostic examinations (e.g. in vitrodiagnostic laboratories, laboratory customers, in vitro diagnostics developers and manufacturers, institutions and commercial organizations performing biomedical research, biobanks, and regulatory authorities).
Blood genomic DNA can fragment or degrade after blood collection. Therefore, special measures need to be taken to secure good quality blood samples for genomic DNA analysis. This is particularly relevant for analytical test procedures requiring high molecular weight DNA.
Different dedicated measures need to be taken for preserving blood circulating cell free DNA, which are not described in this Technical Specification. Circulating cell free DNA in blood is covered in CEN/TS 16835-3, Molecular in vitro diagnostic examinations — Specifications for pre-examination processes for venous whole blood — Part 3: Isolated circulating cell free DNA from plasma.
Different dedicated measures need to be taken for collecting, stabilizing, transporting and storing capillary blood as well as for blood collected and stored by paper based technologies. These are not described in this Technical Specification.
DNA from pathogens present in blood is not covered by this Technical Specification.