CEI EN 62220-1-1 Medical electrical equipment - Characteristics of digital x-ray imaging devices Part 1: Determination of the detective quantum efficiency - Detectors used in radiographic imaging
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ISO ISO/IEC 7816-4 Identification cards - Integrated circuit cards - Part 4: Organization, security and commands for interchange - Third Edition
- 35
- ISO ISO/IEC 7816-4 Identification cards - Integrated circuit cards - Part 4: Organization, security and commands for interchange - Third Edition
- 35.240
- ISO ISO/IEC 19795-2 Information technology - Biometric performance testing and reporting - Part 2: Testing methodologies for technology and scenario evaluation - First Edition
- ISO ISO/IEC 19795-2 Information technology - Biometric performance testing and reporting - Part 2: Testing methodologies for technology and scenario evaluation - First Edition
- BSI PD ISO/IEC TR 19795-3 Information technology - Biometric performance testing and reporting - Part 3: Modality-specific testing
- BSI BS ISO/IEC 19795-5 Information technology - Biometric performance testing and reporting Part 5: Access control scenario and grading scheme
- BSI BS ISO/IEC 19794-8 + A1 Information technology - Biometric data interchange formats Part 8: Finger pattern skeletal data - CORR: May 31, 2012; AMD: May 31, 2014
- ISO 12233 Photography - Electronic still picture imaging - Resolution and spatial frequency responses - Second Edition
- Картотека зарубежных и международных стандартов
Comitato Elettrotecnico Italiano
Medical electrical equipment - Characteristics of digital x-ray imaging devices Part 1: Determination of the detective quantum efficiency - Detectors used in radiographic imaging
N EN 62220-1-1
Annotation
This part of IEC 62220 specifies the method for the determination of the DETECTIVE QUANTUM EFFICIENCY (DQE) of DIGITAL X-RAY IMAGING DEVICES as a function of AIR KERMA and of SPATIAL FREQUENCY for the working conditions in the range of the medical application as specified by the MANUFACTURER. The intended users of this part of IEC 62220 are manufacturers and well equipped test laboratories.
NOTE 1 While not recommended, applying this standard to determine the DQE of digital X-ray imaging devices integrated in a clinical system is not excluded as long as the requirements as set in this standard are respected. Points of additional attention could be (for example but not exclusively) the establishment of the required RADIATION QUALITIES, minimizing influences of scattered and back-scattered radiation, accurate AIR KERMA measurements, positioning of the TEST DEVICE, presence of protective covers, removal of ANTI-SCATTER GRID.
This Part 1-1 is restricted to DIGITAL X-RAY IMAGING DEVICES that are used for radiographic imaging such as, but not exclusively, CR systems, direct and indirect flat panel-detector based systems.
It is not recommended to use this part of IEC 62220 for digital X-RAY IMAGE INTENSIFIER-based systems.
NOTE 2 The use of this standard for X-RAY IMAGE INTENSIFER-based systems is discouraged based on the low frequency drop, vignetting and geometrical distortion present in these devices which may put severe limitations on the applicability of the measurement methods described in this standard.
This part of IEC 62220 is not applicable to: