DNV GL DNV-OS-J103 Design of Floating Wind Turbine Structures
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- DNVGL DNV-OS-J101 Design of Offshore Wind Turbine Structures
- JSA JIS C 3152 Tin Coated Annealed Copper Wires
- JSA JIS C 3502 Coaxial cables for television receivers
- JSA JIS C 3005 Test methods for rubber or plastic insulated wires and cables
- JSA JIS C 3502 Coaxial cables for television receivers
- 29
- JSA JIS C 3152 Tin Coated Annealed Copper Wires
- JSA JIS C 3502 Coaxial cables for television receivers
- JSA JIS C 3005 Test methods for rubber or plastic insulated wires and cables
- JSA JIS C 3502 Coaxial cables for television receivers
- 29.060
- JSA JIS C 3152 Tin Coated Annealed Copper Wires
- JSA JIS C 3502 Coaxial cables for television receivers
- JSA JIS C 3005 Test methods for rubber or plastic insulated wires and cables
- JSA JIS C 3502 Coaxial cables for television receivers
- 29.060.10
- JSA JIS C 3152 Tin Coated Annealed Copper Wires
- JSA JIS C 3502 Coaxial cables for television receivers
- JSA JIS C 3005 Test methods for rubber or plastic insulated wires and cables
- JSA JIS C 3502 Coaxial cables for television receivers
- JSA JIS C 3152 Tin Coated Annealed Copper Wires
- JSA JIS C 3152 Tin Coated Annealed Copper Wires
- JSA JIS C 3152 Tin Coated Annealed Copper Wires
- JSA JIS C 3408 Travelling cables for elevators
- JSA JIS C 3152 Tin Coated Annealed Copper Wires
- JSA JIS C 3502 Coaxial cables for television receivers
- JSA JIS C 3005 Test methods for rubber or plastic insulated wires and cables
- JSA JIS C 3502 Coaxial cables for television receivers
- JSA JIS C 3152 Tin Coated Annealed Copper Wires
- JSA JIS C 3502 Coaxial cables for television receivers
- JSA JIS C 3005 Test methods for rubber or plastic insulated wires and cables
- JSA JIS C 3005 Test methods for rubber or plastic insulated wires and cables
- IEC 60502-2 Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) – Part 2: Cables for rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV) - Edition 3.0
- API SPEC 17E Specification for Subsea Umbilicals - Fourth Edition; Effective APRIL 1, 2011
- DNV GL DNV-RP-F109 On-Bottom Stability Design of Submarine Pipelines - Incorporates Amendment: November 2011
- Картотека зарубежных и международных стандартов
Det Norske Veritas - Germanischer Lloyd
Design of Floating Wind Turbine Structures
N DNV-OS-J103
Annotation
Scope and application
The standard is applicable to all types of support structures and station keeping systems for floating wind turbines.
The standard is applicable to the design of complete structures, including substructures, but excluding wind turbine components such as nacelles and rotors.
This standard gives requirements for the following:
- design principles
- selection of material and extent of inspection in manufacturing yard
- design loads
- load effect analyses
- load combinations
- structural design
- station keeping
- anchoring
- corrosion protection
- transport and installation
- in-service inspection
- power cable design.
Автоматический перевод:



