ISO ISO/IEC 14543-3-11 Information technology – Home electronic system (HES) architecture – Part 3-11: Frequency modulated wireless short-packet (FMWSP) protocol optimised for energy harvesting – Architecture and lower layer protocols - First Edition
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- BSI BS ISO/IEC 27036-3 Information technology — Security techniques — Information security for supplier relationships Part 3: Guidelines for information and communication technology supply chain security
- 35
- BSI BS ISO/IEC 27036-3 Information technology — Security techniques — Information security for supplier relationships Part 3: Guidelines for information and communication technology supply chain security
- 35.040
- CEN EN 16348 Gas infrastructure - Safety Management System (SMS) for gas transmission infrastructure and Pipeline Integrity Management System (PIMS) for gas transmission pipelines - Functional requirements
- CEN EN ISO 14001 Environmental management systems - Requirements with guidance for use
- SNV SN EN 16348 Gas infrastructure - Safety Management System (SMS) for gas transmission infrastructure and Pipeline Integrity Management System (PIMS) for gas transmission pipelines - Functional requirements
- ISO 14001 CORR 1 Environmental management systems — Requirements with guidance for use — TECHNICAL CORRIGENDUM 1 - Deuxieme Edition
- SNV SN EN 16348 Gas infrastructure - Safety Management System (SMS) for gas transmission infrastructure and Pipeline Integrity Management System (PIMS) for gas transmission pipelines - Functional requirements
- CEN EN ISO 14001 Environmental management systems - Requirements with guidance for use
- 23
- CEN EN 16348 Gas infrastructure - Safety Management System (SMS) for gas transmission infrastructure and Pipeline Integrity Management System (PIMS) for gas transmission pipelines - Functional requirements
- CEN EN ISO 14001 Environmental management systems - Requirements with guidance for use
- SNV SN EN 16348 Gas infrastructure - Safety Management System (SMS) for gas transmission infrastructure and Pipeline Integrity Management System (PIMS) for gas transmission pipelines - Functional requirements
- ISO 14001 CORR 1 Environmental management systems — Requirements with guidance for use — TECHNICAL CORRIGENDUM 1 - Deuxieme Edition
- SNV SN EN 16348 Gas infrastructure - Safety Management System (SMS) for gas transmission infrastructure and Pipeline Integrity Management System (PIMS) for gas transmission pipelines - Functional requirements
- CEN EN ISO 14001 Environmental management systems - Requirements with guidance for use
- CEN EN 16348 Gas infrastructure - Safety Management System (SMS) for gas transmission infrastructure and Pipeline Integrity Management System (PIMS) for gas transmission pipelines - Functional requirements
- CEN EN ISO 14001 Environmental management systems - Requirements with guidance for use
- SNV SN EN 16348 Gas infrastructure - Safety Management System (SMS) for gas transmission infrastructure and Pipeline Integrity Management System (PIMS) for gas transmission pipelines - Functional requirements
- ISO 14001 CORR 1 Environmental management systems — Requirements with guidance for use — TECHNICAL CORRIGENDUM 1 - Deuxieme Edition
- SNV SN EN 16348 Gas infrastructure - Safety Management System (SMS) for gas transmission infrastructure and Pipeline Integrity Management System (PIMS) for gas transmission pipelines - Functional requirements
- SNV SN EN 16348 Gas infrastructure - Safety Management System (SMS) for gas transmission infrastructure and Pipeline Integrity Management System (PIMS) for gas transmission pipelines - Functional requirements
- ISO 14001 CORR 1 Environmental management systems — Requirements with guidance for use — TECHNICAL CORRIGENDUM 1 - Deuxieme Edition
- ISO 14001 CORR 1 Environmental management systems — Requirements with guidance for use — TECHNICAL CORRIGENDUM 1 - Deuxieme Edition
- DIN ISO/IEC 27001 Information technology - Security techniques - Information security management systems - Requirements (ISO/IEC 27001:2013 + Cor. 1:2014)
- VDI VDI/VDE 2182 BLATT 1 IT-security for industrial automation - General model
- ISO ISO/IEC 27004 Information technology - Security techniques - Information security management - Measurement - First Edition
- ISO ISO/IEC 30100-2 Information technology – Home network resource management – Part 2: Architecture - First Edition
- Картотека зарубежных и международных стандартов
International Organization for Standardization
Information technology – Home electronic system (HES) architecture – Part 3-11: Frequency modulated wireless short-packet (FMWSP) protocol optimised for energy harvesting – Architecture and lower layer protocols - First Edition
N ISO/IEC 14543-3-11
Annotation
This part of ISO/IEC 14543 specifies a frequency modulated wireless protocol for lowpowered devices such as energy harvested devices in a home environment. This wireless protocol is specifically designed to keep the energy consumption of such sensors and switches extremely low.
The design is characterised by
• keeping the communications very short, infrequent and mostly unidirectional, and
• using communication frequencies that provide a good range even at low transmit power and avoid collisions from disturbers.
This allows the use of small and low cost energy harvesters that can compete with similar batteries-powered devices. The messages sent by energy harvested devices are received and processed mainly by line-powered devices such as relay switch actuators, repeaters or gateways. Together these form part of a home automation system, which, when conforming to the ISO/IEC 14543 series of standards, is defined as a Home Electronic System.
This part of ISO/IEC 14543 specifies OSI Layers 1 to 3 of the Frequency Modulated Wireless Short-Packet (FMWSP) protocol. It makes use of a frequency modulated signal well adapted to mobile devices and also supports high frequency wireless communications.
The FMWSP protocol system consists of two, and optionally three types of components that are specified in this standard. These are the transmitter, the receiver and optionally the repeater. Repeaters are needed when the transmitter and the receiver are located such that no good direct communication between them can be established. By direct communications the functional distance of the system is up to 300 m line-of-sight including the Fresnel zone and up to 30 m in buildings.



