ASTM C1623 Standard Specification for Manufactured Concrete Masonry Lintels
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM C816 Standard Test Method for Sulfur in Graphite by Combustion-Iodometric Titration Method
- 71
- ASTM C816 Standard Test Method for Sulfur in Graphite by Combustion-Iodometric Titration Method
- 71.060
- ASTM C561 Standard Test Method for Ash in a Graphite Sample
- ASTM C561 Standard Test Method for Ash in a Graphite Sample
- ASTM F2191/F2191M Standard Specification for Packing Material, Graphitic or Carbon Braided Yarn
- ASTM C135 Standard Test Method for True Specific Gravity of Refractory Materials by Water Immersion
- ASTM C1240 Standard Specification for Silica Fume Used in Cementitious Mixtures
- Картотека зарубежных и международных стандартов
ASTM International
Standard Specification for Manufactured Concrete Masonry Lintels
N C1623
Annotation
This specification covers concrete masonry lintels (beams) that are solid in cross-section, are reinforced for flexure, and are made from hydraulic cement, water, and mineral aggregates with or without the inclusion of other materials. These lintels are suitable for both loadbearing and nonloadbearing applications.
NOTE 1—This specification covers only concrete masonry lintels containing reinforcement. Due to building code imposed limitations on the design of masonry lintels, all lintels must contain reinforcement. Concrete masonry lintels are not typically manufactured using shear reinforcement (stirrups or other vertical reinforcement). Therefore, this standard does not address issues related to such. For further guidance, refer to Building Code Requirements for Masonry Structures, TMS 402/ACI 530/ASCE 5. Prestressed concrete lintels are not covered by this standard.
Lintels are manufactured using a no-slump concrete mix to provide a surface texture similar to that of concrete masonry. This specification applies to both machine-made and handtamped concrete masonry lintels intended for use in concrete masonry applications.
Concrete masonry lintels covered by this specification are made from lightweight or normal weight aggregates, or both.
This specification does not address the design or analysis of lintel capacity. Structural evaluations must be performed separately. The strength of a lintel is a function of factors including, but not limited to, the characteristics of the materials used in manufacturing (concrete materials and reinforcement), the amount and location of reinforcement, and the manufacturing and curing procedures. For design and analysis methods, refer to Building Code Requirements for Masonry Structures, TMS 402/ACI 530/ASCE 5.