ASTM E779 Standard Test Method for Determining Air Leakage Rate by Fan Pressurization
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM E1827 Standard Test Methods for Determining Airtightness of Buildings Using an Orifice Blower Door
- ASTM E2102 Standard Test Method for Measurement of Mass Loss and Ignitability for Screening Purposes Using a Conical Radiant Heater
- 13
- ASTM E2102 Standard Test Method for Measurement of Mass Loss and Ignitability for Screening Purposes Using a Conical Radiant Heater
- 13.220
- ASTM E2102 Standard Test Method for Measurement of Mass Loss and Ignitability for Screening Purposes Using a Conical Radiant Heater
- 13.220.40
- ASTM E4 Standard Practices for Force Verification of Testing Machines
- ASTM E855 Standard Test Methods for Bend Testing of Metallic Flat Materials for Spring Applications Involving Static Loading
- ASTM E855 Standard Test Methods for Bend Testing of Metallic Flat Materials for Spring Applications Involving Static Loading
- ASTM E691 Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method
- ASTM E535 Standard Practice for Preparation of Fire-Test-Response Standards
- ASTM E456 REV A Standard Terminology Relating to Quality and Statistics
- ASTM E1998 Standard Guide for Assessing Depressurization-Induced Backdrafting and Spillage from Vented Combustion Appliances
- Картотека зарубежных и международных стандартов
ASTM International
Standard Test Method for Determining Air Leakage Rate by Fan Pressurization
N E779
Annotation
This test method measures air-leakage rates through a building envelope under controlled pressurization and depressurization.
This test method is applicable to small temperature differentials and low-wind pressure differential, therefore strong winds and large indoor-outdoor temperature differentials shall be avoided.
This test method is intended to quantify the air tightness of a building envelope. This test method does not measure air change rate or air leakage rate under normal weather conditions and building operation.
NOTE 1—See Test Method E741 to directly measure air-change rates using the tracer gas dilution method
This test method is intended to be used for measuring the air tightness of building envelopes of single-zone buildings. For the purpose of this test method, many multi-zone buildings can be treated as single-zone buildings by opening interior doors or by inducing equal pressures in adjacent zones.
Only metric SI units of measurement are used in this standard. If a value for measurement is followed by a value in other units in parentheses, the second value may be approximate. The first stated value is the requirement.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements see Section 7.