ASTM D8026 Standard Practice for Determination of Tc-99 in Water by Inductively Coupled Plasma Mass Spectrometry (ICP-MS)
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM D7202 Standard Test Method for Determination of Beryllium in the Workplace by Extraction and Optical Fluorescence Detection
- 13
- ASTM E855 Standard Test Methods for Bend Testing of Metallic Flat Materials for Spring Applications Involving Static Loading
- ASTM E691 Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method
- ASTM E691 Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method
- ASTM E70 Standard Test Method for pH of Aqueous Solutions With the Glass Electrode
- ULC CAN/ULC-S563-06 STANDARD FOR CATEGORY 3 FILM-FORMING FLUOROPROTEIN (FFFP) FOAM LIQUID CONCENTRATES - Second Edition
- ULC ULC-S564-06 STANDARD FOR CATEGORIES 1 AND 2 FOAM LIQUID CONCENTRATES - Second Edition
- ULC CAN/ULC-S560-06 STANDARD FOR CATEGORY 3 AQUEOUS FILM-FORMING FOAM (AFFF) LIQUID CONCENTRATES - Second Edition
- ASTM D7168 Standard Test Method for 99Tc in Water by Solid Phase Extraction Disk
- Картотека зарубежных и международных стандартов
ASTM International
Standard Practice for Determination of Tc-99 in Water by Inductively Coupled Plasma Mass Spectrometry (ICP-MS)
N D8026
Annotation
Technetium is separated and concentrated from a water sample by extraction chromatography using its chemical analog, rhenium, as a tracer. The ratio of technetium to rhenium is measured by inductively coupled plasma mass spectrometry (ICP-MS) to then quantify the 99Tc concentration.
This practice is provided as an alternative to Test Method D7168 which provides for a different separation media geometry and measurement by liquid scintillation spectrometry. Similar detection limits should be attainable by this method.
The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.