ASTM D2010/D2010M Standard Test Methods for Evaluation of Total Sulfation Activity in the Atmosphere by the Lead Dioxide Technique
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM D5835 Standard Practice for Sampling Stationary Source Emissions for the Automated Determination of Gas Concentrations
- 13
- ASTM D5835 Standard Practice for Sampling Stationary Source Emissions for the Automated Determination of Gas Concentrations
- 13.040
- ASTM D5156 Standard Test Methods for Continuous Measurement of Ozone in Ambient, Workplace, and Indoor Atmospheres (Ultraviolet Absorption)
- ASTM D1914 Standard Practice for Conversion Units and Factors Relating to Sampling and Analysis of Atmospheres
- ASTM D5149 Standard Test Method for Ozone in the Atmosphere: Continuous Measurement by Ethylene Chemiluminescence
- ASTM D1357 Standard Practice for Planning the Sampling of the Ambient Atmosphere
- ASTM D1608 Standard Test Method for Oxides of Nitrogen in Gaseous Combustion Products (Phenol-Disulfonic Acid Procedures)
- ASTM DS55S5S6S8 Interlaboratory Cooperative Study of Air Quality Measurement Methods
- Картотека зарубежных и международных стандартов
ASTM International
Standard Test Methods for Evaluation of Total Sulfation Activity in the Atmosphere by the Lead Dioxide Technique
N D2010/D2010M
Annotation
These test methods describe the evaluation of the total sulfation activity in the atmosphere. Because of its oxidizing power, lead dioxide (PbO2) converts not only sulfur dioxide (SO2), but other compounds, such as mercaptans and hydrogen sulfide, into sulfate. It fixes sulfur trioxide and sulfuric acid mist present in the atmosphere (see Note 1).
Test Method A describes the use of a PbO2 candle, and Test Method B describes that of a PbO2 sulfation plate.2
These test methods provide a weighted average effective SO2 level for a 30-day interval.
The results of these test methods correlate approximately with volumetric SO2 concentrations, although the presence of dew or condensed moisture tends to enhance the capture of SO2 onto the candle or plate.
The values stated in SI units shall be regarded as the standard. The values given in brackets are for information only and may be approximate.
NOTE 1—It has been shown that the rate constant of the chemical reaction between SO2 and PbO2 is independent of the concentration of SO2 up to levels of 1000 ppm(v), if 15 % or less of the PbO2 has been reduced (1).3 15 % of the PbO2 is equivalent to 11 to 12 mg of SO2/cm2 per day.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 8.