ASTM E2217 Standard Practice for Design and Construction of Aerospace Cleanrooms and Contamination Controlled Areas
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM F25/F25M Standard Test Method for Sizing and Counting Airborne Particulate Contamination in Cleanrooms and Other Dust-Controlled Areas
- 13
- ISO 15388 Space systems — Contamination and cleanliness control - Second Edition
- ASTM E1559 Standard Test Method for Contamination Outgassing Characteristics of Spacecraft Materials
- ASTM E1548 Standard Practice for Preparation of Aerospace Contamination Control Plans
- ASTM F303 Standard Practices for Sampling for Particles in Aerospace Fluids and Components
- ASTM E1548 Standard Practice for Preparation of Aerospace Contamination Control Plans
- ASTM E1559 Standard Test Method for Contamination Outgassing Characteristics of Spacecraft Materials
- ASTM E1559 Standard Test Method for Contamination Outgassing Characteristics of Spacecraft Materials
- ASTM E1548 Standard Practice for Preparation of Aerospace Contamination Control Plans
- ASTM F303 Standard Practices for Sampling for Particles in Aerospace Fluids and Components
- ASTM E1548 Standard Practice for Preparation of Aerospace Contamination Control Plans
- ASTM E1548 Standard Practice for Preparation of Aerospace Contamination Control Plans
- ASTM F303 Standard Practices for Sampling for Particles in Aerospace Fluids and Components
- ASTM F303 Standard Practices for Sampling for Particles in Aerospace Fluids and Components
- ASTM F331 Standard Test Method for Nonvolatile Residue of Solvent Extract from Aerospace Components (Using Flash Evaporator)
- ASTM G136 Standard Practice for Determination of Soluble Residual Contaminants in Materials by Ultrasonic Extraction
- ASTM G120 Standard Practice for Determination of Soluble Residual Contamination by Soxhlet Extraction
- ASTM E1731 Standard Test Method for Gravimetric Determination of Nonvolatile Residue from Cleanroom Gloves
- Картотека зарубежных и международных стандартов
ASTM International
Standard Practice for Design and Construction of Aerospace Cleanrooms and Contamination Controlled Areas
N E2217
Annotation
The purpose of this practice is to provide design and construction guidelines for contamination controlled facilities used in the assembly and integration of aerospace hardware. The guidelines herein are intended to ensure that the facilities, when used properly, will meet the cleanliness requirements of aerospace hardware and processes. The objective is to limit contamination due to the deposition of particulate and molecular contaminants on flight hardware surfaces.
One cleanliness classification of a facility is the airborne particle concentrations in accordance with ISO 14644-1 and 14644-2. Airborne particle concentrations in accordance with FED-STD-209E are included for reference. This simple classification is inadequate to describe a facility that will support the assembly and integration of spacecraft. The extended duration of hardware exposure during fabrication and testing, the sensitivity of the hardware to hydrocarbons and other molecular contaminants, and the changing requirements during assembly and integration must be considered in addition to the airborne particle concentrations.
The guidelines specified herein are intended to provide facilities that will effectively restrict contaminants from entering the facility, limit contamination generated by and within the facility, and continuously remove airborne contaminants generated during normal operations. Some items of support hardware, such as lifting equipment, stands, and shoe cleaners, are addressed since these items are often purchased and installed with the facility and may require accommodation in the design of the facility.
Active filtration of molecular contaminants (such as hydrocarbons, silicones, and other chemicals) is discussed. Such active filtration of molecular contaminants may be required for the processing of highly sensitive optical devices, especially infrared and cryogenic sensors. Control of microbiological contamination is not included although HEPA (High Efficiency Particulate Air) filtration will provide some control of airborne bacteria, spores, and other viable contaminants that are typically carried on particles of sizes 0.3 µm and larger. Control of radioactive contamination and accommodation of very hazardous materials such as propellants, strong acids or caustics, or carcinogens are not addressed.