ASTM C757 Standard Specification for Nuclear-Grade Plutonium Dioxide Powder for Light Water Reactors
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM C1816 Standard Practice for The Ion Exchange Separation of Small Volume Samples Containing Uranium, Americium, and Plutonium Prior to Isotopic Abundance and Content Analysis
- 29
- ASTM C1816 Standard Practice for The Ion Exchange Separation of Small Volume Samples Containing Uranium, Americium, and Plutonium Prior to Isotopic Abundance and Content Analysis
- 29.040
- ASTM C1816 Standard Practice for The Ion Exchange Separation of Small Volume Samples Containing Uranium, Americium, and Plutonium Prior to Isotopic Abundance and Content Analysis
- 29.040.10
- ASTM D7202 Standard Test Method for Determination of Beryllium in the Workplace by Extraction and Optical Fluorescence Detection
- 13
- ASTM C1769 Standard Practice for Analysis of Spent Nuclear Fuel to Determine Selected Isotopes and Estimate Fuel Burnup
- ASTM C1625 Standard Test Method for Uranium and Plutonium Concentrations and Isotopic Abundances by Thermal Ionization Mass Spectrometry
- Картотека зарубежных и международных стандартов
ASTM International
Standard Specification for Nuclear-Grade Plutonium Dioxide Powder for Light Water Reactors
N C757
Annotation
This specification covers nuclear grade PuO2 powder. It applies to PuO2 of various isotopic compositions as normally prepared by in-reactor neutron irradiation of natural or slightly enriched uranium or by in-reactor neutron irradiation of recycled plutonium mixed with uranium.
There is no discussion of or provision for preventing criticality incidents, nor are health and safety requirements, the avoidance of hazards, or shipping precautions and controls discussed. Observance of this specification does not relieve the user of the obligation to be aware of and conform to all applicable international, national, or federal, state, and local regulations pertaining to possessing, shipping, processing, or using source or special nuclear material. For examples in the U.S. Government, relevant documents are Code of Federal Regulations, Title 10 Nuclear Safety Guide, U.S. Atomic Energy Commission Report TID-70162, and “Handbook of Nuclear Safety”, H. K. Clark, U.S. Atomic Energy Commission Report, DP-5322.
The PuO2 shall be produced by a qualified process and in accordance with a quality assurance program approved by the user.
The values stated in SI units are to be regarded as the standard.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2 Available from Superintendent of Documents, U.S. Government Printing Office, 732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20402.