ASTM E959 Standard Test Method for Characterizing the Performance of Refuse Size-Reduction Equipment
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM D7204 Standard Practice for Sampling Waste Streams on Conveyors
- 13
- ASTM D7204 Standard Practice for Sampling Waste Streams on Conveyors
- 13.030
- ASTM D7204 Standard Practice for Sampling Waste Streams on Conveyors
- 13.030.40
- ASTM D6282/D6282M Standard Guide for Direct Push Soil Sampling for Environmental Site Characterizations
- ASTM D1452 Standard Practice for Soil Exploration and Sampling by Auger Borings
- ASTM D1452 Standard Practice for Soil Exploration and Sampling by Auger Borings
- ASTM D6063 Standard Guide for Sampling of Drums and Similar Containers by Field Personnel
- ASTM D5680 Standard Practice for Sampling Unconsolidated Solids in Drums or Similar Containers
- ASTM D6051 Standard Guide for Composite Sampling and Field Subsampling for Environmental Waste Management Activities
- ASTM D6232 Standard Guide for Selection of Sampling Equipment for Waste and Contaminated Media Data Collection Activities
- ASTM D6009 Standard Guide for Sampling Waste Piles
- ASTM D5681 Standard Terminology for Waste and Waste Management
- Картотека зарубежных и международных стандартов
ASTM International
Standard Test Method for Characterizing the Performance of Refuse Size-Reduction Equipment
N E959
Annotation
This test method covers measuring the performance of solid waste size reduction equipment.
This test method can be used to measure the flow (that is, throughput) of solid waste through the size-reduction equipment, energy usage of the size-reduction device, and particle size of the shredded product.
This test method includes instructions for measuring energy usage, solid waste throughput, net processing time, and particle size distribution.
This test method applies only to size reduction equipment that produces a shredded product with a size corresponding to 90 % cumulative passing in the range of 0.5 to 15 cm (0.2–6 in.) on an air-dry weight basis. For material with nominal sizes outside of this range, the precision and bias statements for particle size designation (Section 14) may not apply.
This test method can be applied to size reduction equipment located anywhere within a processing line.
The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
Exception—The values given in parentheses are for information only.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. See Section 7 for specific hazard information.