ASTM C1459 Standard Specification for Performance of Non-Asbestos Fiber-Reinforced Cement Shake, Shingle, and Slate Roofing Systems
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM E2257 REV A Standard Test Method for Room Fire Test of Wall and Ceiling Materials and Assemblies
- 13
- ASTM E2257 REV A Standard Test Method for Room Fire Test of Wall and Ceiling Materials and Assemblies
- 13.220
- ASTM G125 Standard Test Method for Measuring Liquid and Solid Material Fire Limits in Gaseous Oxidants
- ASTM D618 Standard Practice for Conditioning Plastics for Testing
- ASTM D6109 Standard Test Methods for Flexural Properties of Unreinforced and Reinforced Plastic Lumber and Related Products
- ASTM D618 Standard Practice for Conditioning Plastics for Testing
- ASTM D6109 Standard Test Methods for Flexural Properties of Unreinforced and Reinforced Plastic Lumber and Related Products
- ASTM D7032 Standard Specification for Establishing Performance Ratings for Wood-Plastic Composite Deck Boards and Guardrail Systems (Guards or Handrails)
- ASTM E2957 Standard Test Method for Resistance to Wildfire Penetration of Eaves, Soffits and Other Projections
- ASTM E2886/E2886M Standard Test Method for Evaluating the Ability of Exterior Vents to Resist the Entry of Embers and Direct Flame Impingement
- ASTM E108 Standard Test Methods for Fire Tests of Roof Coverings
- Картотека зарубежных и международных стандартов
ASTM International
Standard Specification for Performance of Non-Asbestos Fiber-Reinforced Cement Shake, Shingle, and Slate Roofing Systems
N C1459
Annotation
This specification covers the performance of nonasbestos, fiber-reinforced cement shake, shingle, and slate roofing systems that are of uniform or nonuniform thickness and texture.
This specification does not include details of product installation and workmanship. The manufacturer's installation instructions shall be referred to for details such as slope, interlayment, underlayment, sheathing requirements, exposure, fasteners, and repair or replacement instructions.
This specification does not address requirements for individual shake, shingle, and slate products, which are covered in Specification C1225 and C1530.
The tests contained in this specification are intended as qualification tests for a roofing system. Changes in product formulation, design, or manufacturing process beyond the ranges allowed in the manufacturer's quality control specifications, shall require subsequent system retesting or written concurrence by an independent testing agency that the changes in formulation, design, or manufacturing process will not be detrimental to system performance.
The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.