ASTM E2304 Standard Practice for Use of a LiF Photo-Fluorescent Film Dosimetry System
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM E1879 Standard Guide for Sensory Evaluation of Beverages Containing Alcohol
- ASTM E2262 Standard Practice for Estimating Thurstonian Discriminal Distances
- 67
- ASTM E1879 Standard Guide for Sensory Evaluation of Beverages Containing Alcohol
- ASTM E2262 Standard Practice for Estimating Thurstonian Discriminal Distances
- 67.160
- ASTM E1879 Standard Guide for Sensory Evaluation of Beverages Containing Alcohol
- ASTM E2262 Standard Practice for Estimating Thurstonian Discriminal Distances
- 67.160.10
- ASTM E1879 Standard Guide for Sensory Evaluation of Beverages Containing Alcohol
- ASTM E2262 Standard Practice for Estimating Thurstonian Discriminal Distances
- ASTM E1879 Standard Guide for Sensory Evaluation of Beverages Containing Alcohol
- ASTM E1879 Standard Guide for Sensory Evaluation of Beverages Containing Alcohol
- ASTM E1879 Standard Guide for Sensory Evaluation of Beverages Containing Alcohol
- ASTM E2262 Standard Practice for Estimating Thurstonian Discriminal Distances
- ASTM E2164 Standard Test Method for Directional Difference Test
- ASTM E460 Standard Practice for Determining Effect of Packaging on Food and Beverage Products During Storage
- ASTM F1640 Standard Guide for Selection and Use of Packaging Materials for Foods to Be Irradiated
- ASTM F1355 Standard Guide for Irradiation of Fresh Agricultural Produce as a Phytosanitary Treatment
- ISO/ASTM 51431 Standard Practice for Dosimetry in Electron Beam and X-Ray (Bremsstrahlung) Irradiation Facilities for Food Processing
- ASTM E1879 Standard Guide for Sensory Evaluation of Beverages Containing Alcohol
- Картотека зарубежных и международных стандартов
ASTM International
Standard Practice for Use of a LiF Photo-Fluorescent Film Dosimetry System
N E2304
Annotation
This practice covers the handling, testing, and procedure for using a lithium fluoride (LiF)-based photo-fluorescent film dosimetry system to measure absorbed dose (relative to water) in materials irradiated by photons or electrons. Other alkali halides that may also exhibit photofluorescence (for example, NaCl, NaF, and KCl) are not covered in this practice. Although various alkali halides have been used for dosimetry for years utilizing thermoluminescence, the use of photoluminescence is relatively new.
This practice applies to photo-fluorescent film dosimeters (referred hereafter as photo-fluorescent dosimeters) that can be used within part or all of the following ranges:
Absorbed dose range of 5 10 2 to 3 10 kGy (1-3).2
Absorbed dose rate range of 0.3 to 2 10(4) Gy/s (2-5)).
Radiation energy range for photons of 0.05 to 10 MeV (2).
Radiation energy range for electrons of 0.1 to 10 MeV (2).
Radiation temperature range of 20 to +60°C (6,7).
The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.