ASTM E2450 Standard Practice for Application of CaF2(Mn) Thermoluminescence Dosimeters in Mixed Neutron-Photon Environments
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM ISO/ASTM 51205 Standard Practice for Use of a Ceric-Cerous Sulfate Dosimetry System
- ASTM D3082 Standard Test Method for Boron in Water
- 13
- ASTM D3082 Standard Test Method for Boron in Water
- 13.060
- ASTM D3082 Standard Test Method for Boron in Water
- 13.060.50
- ASTM D3082 Standard Test Method for Boron in Water
- ASTM D3859 Standard Test Methods for Selenium in Water
- ASTM D5810 Standard Guide for Spiking into Aqueous Samples
- ASTM D5996 Standard Test Method for Measuring Anionic Contaminants in High-Purity Water by On-Line Ion Chromatography
- ASTM D3864 Standard Guide for On-Line Monitoring Systems for Water Analysis
- ASTM E178 Standard Practice for Dealing With Outlying Observations
- ASTM E666 Standard Practice for Calculating Absorbed Dose From Gamma or X Radiation
- Картотека зарубежных и международных стандартов
ASTM International
Standard Practice for Application of CaF2(Mn) Thermoluminescence Dosimeters in Mixed Neutron-Photon Environments
N E2450
Annotation
This practice describes a procedure for correcting a CaF2(Mn) thermoluminescence dosimeter (TLD) reading for its response to neutrons during the irradiation. The neutron response may be subtracted from the total TLD response to give the gamma-ray response. In fields with a large neutron contribution to the total response, this procedure may result in large uncertainties.
More precise experimental techniques may be applied if the uncertainty derived from this practice is larger than the level that the user can accept. These more precise techniques are not discussed here. The references in Section 8 describe some of these techniques.
This practice does not discuss effects on the TLD reading from neutron interactions with the material surrounding the TLD and used to ensure a charged particle equilibrium. These effects will depend on the isotopic composition of the surrounding material and its thickness, and on the incident neutron spectrum (1).2
The values stated in SI units are to be regarded as standard.
2 The boldface numbers in parentheses refer to the list of references at the end of this standard.
Автоматический перевод:
Утвержденный технологический процесс для применения CaF2 (Mn) дозирующие устройства термолюминесценции в смешанных окружающих средах Нейтронного Фотона