ASTM E1577 Standard Guide for Reporting of Ion Beam Parameters Used in Surface Analysis
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ISO 14606 Surface Chemical Analysis - Sputter Depth Profiling - Optimization Using Layered Systems as Reference Materials - First Edition
- 71
- ISO 14606 Surface Chemical Analysis - Sputter Depth Profiling - Optimization Using Layered Systems as Reference Materials - First Edition
- 71.040
- ISO 14606 Surface Chemical Analysis - Sputter Depth Profiling - Optimization Using Layered Systems as Reference Materials - First Edition
- 71.040.40
- ISO 14606 Surface Chemical Analysis - Sputter Depth Profiling - Optimization Using Layered Systems as Reference Materials - First Edition
- ISO 18115-1 Surface chemical analysis — Vocabulary — Part 1: General terms and terms used in spectroscopy - First Edition
- 01
- ISO 18115-1 Surface chemical analysis — Vocabulary — Part 1: General terms and terms used in spectroscopy - First Edition
- ISO 16531 Surface chemical analysis - Depth profiling - Methods for ion beam alignment and the associated measurement of current or current density for depth profiling in AES and XPS - First Edition
- ISO 14606 Surface chemical analysis - Sputter depth profiling - Optimization using layered systems as reference materials - Second edition
- ASTM E1127 Standard Guide for Depth Profiling in Auger Electron Spectroscopy
- Картотека зарубежных и международных стандартов
ASTM International
Standard Guide for Reporting of Ion Beam Parameters Used in Surface Analysis
N E1577
Annotation
This guide covers the information needed to characterize ion beams used in surface analysis.
This guide does not cover all information required to perform a sputter depth profile (see referenced documents), specify any properties of the specimen except its surface normal, and discuss the rationale for choosing a particular set of ion beam parameters (1, 2).2 This guide does assume that the ion flux has a unique direction, that is, is an ion beam, rather than a wide spectrum of velocity vectors more typical of a plasma.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2 The boldface numbers given in parentheses refer to a list of references at the end of this guide.