ASTM E2461 Standard Practice for Determining the Thickness of Glass in Airport Traffic Control Tower Cabs
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM E772 Standard Terminology of Solar Energy Conversion
- 01
- 27
- ASTM C1651 Standard Test Method for Measurement of Roll Wave Optical Distortion in Heat-Treated Flat Glass
- ASTM C1036 Standard Specification for Flat Glass
- Картотека зарубежных и международных стандартов
ASTM International
Standard Practice for Determining the Thickness of Glass in Airport Traffic Control Tower Cabs
N ASTM E2461
Annotation
This practice covers the determination of the thickness of glass installed in airport traffic control towers (ATCT) to resist a specified design loading with a selected probability of breakage less than or equal to either 1 lite per 1000 or 4 lites per 1000 at the first occurrence of the design wind loading.
The procedures apply to common outward sloping cab glass designs for which the specified loads do not exceed 10 kPa (210 psf).
The procedures assume control tower cab glass has an aspect ratio no greater than 2.
The procedures assume control tower cab glass has an area no less than 1.86 square metres (20 square feet).
The procedures apply only to annealed monolithic, annealed laminated, or annealed insulating glass having a rectangular or trapezoidal shape.
The use of the procedures assumes the following:
Annealed monolithic and annealed laminated glass installed in ATCTs shall have continuous lateral support along two parallel edges, along any three edges, or along all four edges;
Insulating glass shall have continuous lateral support along all four edges; and
Supported glass edges are simply supported and free to slip in plane.
The procedures do not apply to any form of wired, patterned, etched, sandblasted, or glass types with surface treatments that reduce the glass strength.
The procedures do not apply to any form of heat treated glass, chemically strengthened glass, or any type of glass with surface treatments intended to increase the glass strength.