ISO 17211 Stationary source emissions - Sampling and determination of selenium compounds in flue gas - First Edition
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- CEN CEN/TS 14793 Stationary source emission - Intralaboratory validation procedure for an alternative method compared to a reference method
- 13
- CEN CEN/TS 14793 Stationary source emission - Intralaboratory validation procedure for an alternative method compared to a reference method
- 13.040
- CEN CEN/TS 14793 Stationary source emission - Intralaboratory validation procedure for an alternative method compared to a reference method
- 13.040.40
- BSI DD CEN/TS 14793 Stationary source emission Intralaboratory validation procedure for an alternative method compared to a reference method
- BSI DD CEN/TS 14793 Stationary source emission Intralaboratory validation procedure for an alternative method compared to a reference method
- BSI DD CEN/TS 14793 Stationary source emission Intralaboratory validation procedure for an alternative method compared to a reference method
- ISO 11095 Linear Calibration Using Reference Materials First Edition
- ISO 16911-1 Stationary source emissions - Manual and automatic determination of velocity and volume flow rate in ducts - Part 1: Manual reference method - First Edition
- Картотека зарубежных и международных стандартов
International Organization for Standardization
Stationary source emissions - Sampling and determination of selenium compounds in flue gas - First Edition
N 17211
Annotation
This International Standard describes the method for the sampling and determination of selenium compounds in both vapour phase and solid phase that are entrained in flue gases carried in stacks or ducts. The selenium content in flue gas is expressed as a mass concentration of elemental selenium in the stack gas.
Particulate and gaseous selenium compounds are captured by a filter and an absorber solution, respectively. The total concentration of selenium compounds in flue gas is expressed as the sum of both concentrations.
The concentrations of selenium in both samples are determined using inductively coupled plasma optical emission spectrometry (ICP-OES), inductively coupled plasma mass spectrometry (ICP-MS) or graphite furnace atomic absorption spectrometry (GFAAS). Hydride generation (HG) techniques coupled to atomic spectrometry can also be used such as HG-AAS, HG-AFS (atomic fluorescence spectrometry), HG-ICP-OES and HG-ICP-MS.
The detection limit for gaseous selenium compounds is 0,3 g/m3 using HG-ICP-MS at a sampling volume of 0,12 m3. The detection limit for particulate selenium compounds is 0,001 2 g/m3 using this technique at a sampling volume of 2,0 m3.
Автоматический перевод:
Постоянная исходная эмиссия - Выборка и определение составов селена в дымовом газе - Первый Выпуск