JSA JIS R 1611 Measurement methods of thermal diffusivity, specific heat capacity, and thermal conductivity for fine ceramics by flash method

Список продуктов
Данный раздел/документ содержится в продуктах:

 

Japanese Standards Association

Measurement methods of thermal diffusivity, specific heat capacity, and thermal conductivity for fine ceramics by flash method
 N JIS R 1611

 

Annotation

 

This Standard specifies the test method for the determination of thermal diffusivity from room temperature to 1 700 K, specific heat capacity from room temperature to 1 000 K, and thermal conductivity from room temperature to 1 000 K by the flash method for homogeneous ceramics with porosity 10 % or less.

NOTE: The International Standard corresponding to this Standard and the symbol of degree of correspondence are as follows.

ISO 18755: 2005 Fine ceramics (advanced ceramics, advanced technical ceramics)-Determination of thermal diffusivity of monolithic ceramics by laser flash method (MOD)

In addition, symbols which denote the degree of correspondence in the contents between the relevant International Standard and JIS are IDT (identical), MOD (modified), and NEQ (not equivalent) according to ISO/lEC Guide 21-1.

 

Автоматический перевод:

 

Методы измерения тепловой диффузивности, определенной теплоемкости и теплопроводности для тонкой керамики методом вспышки

Этот Стандарт определяет метод испытаний для определения тепловой диффузивности от комнатной температуры до 1 700 K, определенной теплоемкости от комнатной температуры до 1 000 K и теплопроводности от комнатной температуры до 1 000 K методом вспышки для гомогенной керамики с пористостью 10% или меньше.