CEN EN 674 Glass in building - Determination of thermal transmittance (U value) - Guarded hot plate method

Список продуктов
Данный раздел/документ содержится в продуктах:

 

European Committee for Standardization

Glass in building - Determination of thermal transmittance (U value) - Guarded hot plate method
 N EN 674

 

Annotation

 

This European Standard specifies a measurement method to determine the thermal transmittance of glazing with flat and parallel surfaces. Structured surfaces, e.g. patterned glass, can be considered to be flat.

This European Standard applies to multiple glazing with outer panes which are not transparent to far infrared radiation, which is the case for soda lime silicate glass products, borosilicate glass and glass ceramics. Internal elements may be far infrared transparent.

The procedure specified in this European Standard determines the U value1) (thermal transmittance) in the central area of glazing. The edge effects, due to the thermal bridge through the spacer of an insulating glass unit or through the window frame are not included. Furthermore energy transfer due to solar radiation is not taken into account.

The procedure specified in this European Standard should generally only.

The document for the calculation of the overall U value of windows, doors and shutters (see [3]) gives normative reference to the U value evaluated for the glazing components according to this standard.

A vertical position of the glazing is specified.

U values evaluated according to the present standard are used for product comparison as well as for other purposes, in particular for predicting:

— heat loss through glazing;

— conduction heat gains in summer;

— condensation on glazing surfaces;