CEI EN 61010-2-061 Safety requirements for electrical equipment for measurement, control and laboratory use Part 2-061: Particular requirements for laboratory atomic spectrometers with thermal atomization and ionization
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- IEC 60335-2-9 Household and similar electrical appliances – Safety – Part 2-9: Particular requirements for grills, toasters and similar portable cooking appliances - Edition 6.1 Consolidated Reprint
- 13
- IEC 60335-2-9 Household and similar electrical appliances – Safety – Part 2-9: Particular requirements for grills, toasters and similar portable cooking appliances - Edition 6.1 Consolidated Reprint
- 13.120
- 97
- IEC 60335-2-9 Household and similar electrical appliances – Safety – Part 2-9: Particular requirements for grills, toasters and similar portable cooking appliances - Edition 6.1 Consolidated Reprint
- 97.040
- IEC 60335-2-9 Household and similar electrical appliances – Safety – Part 2-9: Particular requirements for grills, toasters and similar portable cooking appliances - Edition 6.1 Consolidated Reprint
- 97.040.50
- IEC 60335-2-12 Household and similar electrical appliances – Safety – Part 2-12: Particular requirements for warming plates and similar appliances - Edition 5.1 Consolidated Reprint
- Картотека зарубежных и международных стандартов
Comitato Elettrotecnico Italiano
Safety requirements for electrical equipment for measurement, control and laboratory use Part 2-061: Particular requirements for laboratory atomic spectrometers with thermal atomization and ionization
N EN 61010-2-061
Annotation
Equipment included in scope
Replacement:
Replace the text by the following:
This part of IEC 61010 applies to electrically powered laboratory atomic spectrometers with thermal atomization.
NOTE 1 Examples include atomic absorption spectrometers, emission flame photometers, atomic fluorescence spectrophotometers, inductively coupled plasma spectrometers, microwave coupled plasma spectrometers and mass spectrometers, all with thermal atomization and ionization (including tubing and connectors which are provided by the manufacturer for connection to external supplies).
NOTE 2 If all or part of the equipment falls within the scope of one or more other part 2 standards of IEC 61010 as well as within the scope of this standard, consideration is to be given to those other part 2 standards.
Equipment excluded from scope
Addition: Add as the first paragraph:
This standard does not apply to thermal atomization detectors (flame ionization detectors) used in gas chromatography.
Автоматический перевод:
Требования техники безопасности для электрического оборудования для измерения, контроля и лаборатории используют Часть 2-061: Конкретные требования для лабораторных атомных спектрометров с тепловым распылением и ионизацией