API RP 2030 Application of Fixed Water Spray Systems for Fire Protection in the Petroleum and Petrochemical Industries - FOURTH EDITION
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- IEC 60079-10-2 Explosive atmospheres – Part 10-2: Classification of areas – Combustible dust atmospheres - Edition 1.0
- 29
- IEC 60079-10-2 Explosive atmospheres – Part 10-2: Classification of areas – Combustible dust atmospheres - Edition 1.0
- 29.260
- IEC 60079-10-2 Explosive atmospheres – Part 10-2: Classification of areas – Combustible dust atmospheres - Edition 1.0
- 29.260.20
- ASME B31G Manual for Determining the Remaining Strength of Corroded Pipelines
- ASME PTB-9 ASME Pipeline Standards Compendium
- ASME B31.8S Managing System Integrity of Gas Pipelines - Supplement to ASME B31.8
- ASME PTB-9 ASME Pipeline Standards Compendium
- ASME PTB-9 ASME Pipeline Standards Compendium
- ASME B31.8S Managing System Integrity of Gas Pipelines - Supplement to ASME B31.8
- ASME B31.8S Managing System Integrity of Gas Pipelines - Supplement to ASME B31.8
- DIN EN 14161 Petroleum and natural gas industries - Pipeline transportation systems (ISO 13623:2009 modified) (includes Amendment A1:2015)
- ISO 10439 Petroleum, Chemical and Gas Service Industries - Centrifugal Compressors - First Edition
- ASTM A522/A522M Standard Specification for Forged or Rolled 8 and 9% Nickel Alloy Steel Flanges, Fittings, Valves, and Parts for Low-Temperature Service
- API RP 751 Safe Operation of Hydrofluoric Acid Alkylation Units - Fourth Edition
- Картотека зарубежных и международных стандартов
American Petroleum Institute
Application of Fixed Water Spray Systems for Fire Protection in the Petroleum and Petrochemical Industries - FOURTH EDITION
N RP 2030
Annotation
General
When addressing loss prevention, an organization should consider the use of fixed fire protection systems, one of which is water spray systems. Water spray systems appear similar to sprinkler systems in some respects; however, the intended uses, applicable Fire Codes and design criteria differ. This publication provides guidance for the petroleum industry and some petrochemical industry applications (for non-water-reactive petrochemicals with physical and combustion characteristics comparable to hydrocarbons) in determining where water spray systems might be used to provide protection from fire damage for equipment and structures.
Damage to process equipment and structural steel also can be limited by fireproofing, applying water through manual hose streams or applying water from fixed or mobile monitor nozzles; these methods are covered in API Recommended Practice 2218 Fireproofing Practices in Petroleum and Petrochemical Processing Plants, API Recommended Practice 2001 Fire Protection in Refineries and other referenced documents such as the National Fire Protection Association (NFPA) Fire Protection Handbook and various NFPA Codes.
The specifics of water spray system design, installation and component types are covered in the publications referenced in Section 2, principally NFPA 15, and are not duplicated in this publication.
The following other special applications of water spray are outside the scope of this publication:
— foam sprinkler systems used to supplement water spray systems and extinguish flammable liquid fires (see NFPA 16 for details);