ASTM E1672 Standard Guide for Computed Tomography (CT) System Selection
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM E1931 Standard Guide for X-Ray Compton Scatter Tomography
- 35
- VDI 2045 BLATT 1 Acceptance and performance tests on turbo compressors and displacement compressors; test procedure and comparison with guaranteed values
- VDI VDI/VDE 2640 Blatt 3 Measurement of gas flow in circular; annular or rectangular sections of conduits velocity area method
- ISO 5389 Turbocompressors Performance test code - Second Edition
- VDI VDI/VDE 2640 Blatt 3 Measurement of gas flow in circular; annular or rectangular sections of conduits velocity area method
- VDI VDI/VDE 2640 Blatt 3 Measurement of gas flow in circular; annular or rectangular sections of conduits velocity area method
- ISO 5389 Turbocompressors Performance test code - Second Edition
- ISO 5389 Turbocompressors Performance test code - Second Edition
- DIN EN ISO 10439-2 Petroleum, petrochemical and natural gas industries - Axial and centrifugal compressors and expander-compressors - Part 2: Non-integrally geared centrifugal and axial compressors (ISO 10439-2:2015)
- API STD 670 Machinery Protection Systems - FIFTH EDITION
- ASTM E1934 REV A Standard Guide for Examining Electrical and Mechanical Equipment with Infrared Thermography
- ASTM E2533 Standard Guide for Nondestructive Testing of Polymer Matrix Composites Used in Aerospace Applications
- ASTM E1441 Standard Guide for Computed Tomography (CT) Imaging
- Картотека зарубежных и международных стандартов
ASTM International
Standard Guide for Computed Tomography (CT) System Selection
N E1672
Annotation
This guide covers guidelines for translating application requirements into computed tomography (CT) system requirements/specifications and establishes a common terminology to guide both purchaser and supplier in the CT system selection process. This guide is applicable to the purchaser of both CT systems and scan services. Computed tomography systems are complex instruments, consisting of many components that must correctly interact in order to yield images that repeatedly reproduce satisfactory examination results. Computed tomography system purchasers are generally concerned with application requirements. Computed tomography system suppliers are generally concerned with the system component selection to meet the purchaser's performance requirements. This guide is not intended to be limiting or restrictive, but rather to address the relationships between application requirements and performance specifications that must be understood and considered for proper CT system selection.
Computed tomography (CT) may be used for new applications or in place of radiography or radioscopy, provided that the capability to disclose physical features or indications that form the acceptance/rejection criteria is fully documented and available for review. In general, CT has lower spatial resolution than film radiography and is of comparable spatial resolution with digital radiography or radioscopy unless magnification is used. Magnification can be used in CT or radiography/radioscopy to increase spatial resolution but concurrently with loss of field of view.
Computed tomography (CT) systems use a set of transmission measurements made along a set of paths projected through the object from many different directions. Each of the transmission measurements within these views is digitized and stored in a computer, where they are subsequently conditioned (for example, normalized and corrected) and reconstructed, typically into slices of the object normal to the set of projection paths by one of a variety of techniques. If many slices are reconstructed, a three dimensional representation of the object is obtained. An in-depth treatment of CT principles is given in Guide E1441.