VDI VDI/VDE/DWA 3552 Use of field bus systems in water supply plants
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- VDI VDI/VDE 2650 BLATT 2 Requirements regarding self-monitoring and diagnosis in field instrumentation - General faults and fault conditions
- 35
- CENELEC CLC/TR 62685 Industrial communication networks - Profiles - Assessment guideline for safety devices using IEC 61784-3 functional safety communication profiles (FSCPs)
- IEC 61010-2-030 CORR 1 CORRIGENDUM 1 SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE – Part 2-030: Particular requirements for testing and measuring circuits - Edition 1.0
- IEC 61010-2-030 CORR 1 CORRIGENDUM 1 SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE – Part 2-030: Particular requirements for testing and measuring circuits - Edition 1.0
- CENELEC EN 61784-1 Industrial communication networks - Profiles - Part 1: Fieldbus profiles
- CENELEC EN 62769-101-2 Field Device Integration (FDI) - Part 101-2: Profiles - Foundation Fieldbus HSE
- CENELEC EN 62541-100 OPC unified architecture - Part 100: Device Interface
- CENELEC EN 62769-109-1 Field Device Integration (FDI) - Part 109-1: Profiles - HART(r) and WirelessHART(r)
- IEC 61804-5 Function blocks (FB) for process control and electronic device description language (EDDL) - Part 5: EDDL Builtin library - Edition 1.0
- Картотека зарубежных и международных стандартов
Verein Deutscher Ingenieure
Use of field bus systems in water supply plants
N VDI/VDE/DWA 3552
Annotation
Scope of application
Objective
For field bus communication to work optimally with field devices, devices of the same type, even if not from the same manufacturer, have to behave in the same way. This can only be achieved by standardizing not only communication (i.e. selecting a standardized field bus), but also those device functions and device parameters which are accessed via the field bus. This end is served by a profile that is based on a device model.
This guideline is dedicated to the task of ensuring that, for the field of water management and the pertinent requirements, the relevant device parameters and functionalities are defined in a profile.
Existing device profiles (PROFIBUS PA profiles V 3.01) serve as templates for this task. This guideline is, consequently, an extension of existing device profiles.
The specific scope of this guideline is given by the use of profiles of field buses in municipal and industrial water, wastewater and sewage treatment plants (water management plants).
This guideline defines the behaviour of field devices as visible through a communication system, differentiating by:
• measuring devices
• analysers
• control valves
The guideline does not cover, e.g., programmable logic controllers, process data servers, parameterising tools, engineering stations and operator stations.