CENELEC EN 62287-2 Maritime navigation and radiocommunication equipment and systems - Class B shipborne equipment of the automatic identification system (AIS) - Part 2: Self-organising time division multiple access (SOTDMA) techniques
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- BSI PD CLC/TS 50576 Electric cables — Extended application of test results
- CENELEC EN 60332-1-2 Tests on electric and optical fibre cables under fire conditions Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame
- 13
- BSI PD CLC/TS 50576 Electric cables — Extended application of test results
- CENELEC EN 60332-1-2 Tests on electric and optical fibre cables under fire conditions Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame
- 13.220
- BSI PD CLC/TS 50576 Electric cables — Extended application of test results
- CENELEC EN 60332-1-2 Tests on electric and optical fibre cables under fire conditions Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame
- 13.220.40
- BSI PD CLC/TS 50576 Electric cables — Extended application of test results
- CENELEC EN 60332-1-2 Tests on electric and optical fibre cables under fire conditions Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame
- BSI PD CLC/TS 50576 Electric cables — Extended application of test results
- BSI PD CLC/TS 50576 Electric cables — Extended application of test results
- BSI PD CLC/TS 50576 Electric cables — Extended application of test results
- 29
- BSI PD CLC/TS 50576 Electric cables — Extended application of test results
- CENELEC EN 60332-1-2 Tests on electric and optical fibre cables under fire conditions Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame
- 29.060
- BSI PD CLC/TS 50576 Electric cables — Extended application of test results
- CENELEC EN 60332-1-2 Tests on electric and optical fibre cables under fire conditions Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame
- BSI PD CLC/TS 50576 Electric cables — Extended application of test results
- BSI PD CLC/TS 50576 Electric cables — Extended application of test results
- CENELEC EN 60332-1-2 Tests on electric and optical fibre cables under fire conditions Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame
- BSI BS EN 60332-1-3 + A1 Tests on electric and optical fibre cables under fire conditions - Part 1-3: Test for vertical flame propagation for a single insulated wire or cable - Procedure for determination of flaming droplets/particles - AMD: October 31, 2015
- CENELEC EN 61162-2 Maritime Navigation and Radiocommunication Equipment and Systems Digital Interfaces Part 2: Single Talker and Multiple Listeners, High-Speed Transmission
- BSI PD CLC/TS 50576 Electric cables — Extended application of test results
- Картотека зарубежных и международных стандартов
European Committee for Electrotechnical Standardization
Maritime navigation and radiocommunication equipment and systems - Class B shipborne equipment of the automatic identification system (AIS) - Part 2: Self-organising time division multiple access (SOTDMA) techniques
N EN 62287-2
Annotation
This part of IEC 62287 specifies operational and performance requirements, methods of testing and required test results for Class B "SO" shipborne AIS equipment using Selforganised TDMA (SOTDMA) techniques as described in Recommendation ITU-R M.1371. This standard takes into account other associated IEC International Standards and existing national standards, as applicable.
The main differences between Class B "CS" (IEC 62287-1) and Class B "SO" units are that the Class B "SO":
• covers all 25 kHz channels listed in Recommendation ITU-R M.1084-5;
• only uses the internal GNSS, no position sensor input is allowed;
• requires use of VDL Message 17 for correction of the internal GNSS;
• has a presentation interface;
• has additional reporting intervals, down to 5 s;
• has two power settings, with a high level of 5 W;
• has the capability to transmit binary messages.
It is applicable for AIS equipment used on craft that are not covered by a mandatory carriage requirement of AIS under SOLAS Chapter V.



