IEC 61000-4-13 Electromagnetic compatibility (EMC) – Part 4-13: Testing and measurement techniques – Harmonics and interharmonics including mains signalling at a.c. power port, low frequency immunity tests - Edition 1.1 Consolidated Reprint
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- CEI EN 61000-4-25/A1 Electromagnetic compatibility (EMC) Part 4-25: Testing and measurement techniques - HEMP immunity test methods for equipment and systems
- 33
- CEI EN 61000-4-25/A1 Electromagnetic compatibility (EMC) Part 4-25: Testing and measurement techniques - HEMP immunity test methods for equipment and systems
- 33.100
- IEC TS 60479-1 CORR 1 Effects of current on human beings and livestock – Part 1: General aspects CORRIGENDUM 1 - Edition 4.0
- IEC TR 60479-4 Effects of current on human beings and livestock – Part 4: Effects of lightning strokes - Edition 2.0
- IEC TR 60479-4 Effects of current on human beings and livestock – Part 4: Effects of lightning strokes - Edition 2.0
- IEC TS 60479-1 CORR 2 Effects of current on human beings and livestock – Part 1: General aspects CORRIGENDUM 2 - Edition 4.0
- IEC TS 61936-2 Power installations exceeding 1 kV a.c. and 1,5 kV d.c. – Part 2: d.c. - Edition 1.0
- IEC TR 62544 High-voltage direct current (HVDC) systems – Application of active filters - Edition 1.0
- IEC 61000-6-6 Electromagnetic compatibility (EMC) Part 6-6: Generic standards HEMP immunity for indoor equipment - Edition 1.0
- Картотека зарубежных и международных стандартов
International Electrotechnical Commission
Electromagnetic compatibility (EMC) – Part 4-13: Testing and measurement techniques – Harmonics and interharmonics including mains signalling at a.c. power port, low frequency immunity tests - Edition 1.1 Consolidated Reprint
N 61000-4-13
Annotation
Scope and object
This part of IEC 61000 defines the immunity test methods and range of recommended basic test levels for electrical and electronic equipment with rated current up to 16 A per phase at disturbance frequencies up to and including 2 kHz (for 50 Hz mains) and 2,4 kHz (for 60 Hz mains) for harmonics and interharmonics on low voltage power networks.
It does not apply to electrical and electronic equipment connected to 16 2/3 Hz , or to 400 Hz a.c. networks. Tests for these networks will be covered by future standards.
The object of this standard is to establish a common reference for evaluating the functional immunity of electrical and electronic equipment when subjected to harmonics and interharmonics and mains signalling frequencies. The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon. As described in IEC guide 107, this is a basic EMC publication for use by product committees of the IEC. As also stated in Guide 107, the IEC product committees are responsible for determining whether this immunity test standard should be applied or not, and if applied, they are responsible for determining the appropriate test levels and performance criteria. TC 77 and its sub-committees are prepared to co-operate with product committees in the evaluation of the value of particular immunity tests for their products.
The verification of the reliability of electrical components (for example capacitors, filters, etc.) is not in the scope of the present standard. Long term thermal effects (greater than 15 min) are not considered in this standard.