ASME TDP-1 Prevention of Water Damage to Steam Turbines Used for Electric Power Generation: Fossil-Fueled Plants
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM F1412 Standard Specification for Polyolefin Pipe and Fittings for Corrosive Waste Drainage Systems
- 23
- ASME B31E Standard for the Seismic Design and Retrofit of Above-Ground Piping Systems
- ASME B16.21 Nonmetallic Flat Gaskets for Pipe Flanges
- ASTM F363 Standard Test Method for Corrosion Testing of Gaskets
- ASTM F112 Standard Test Method for Sealability of Enveloped Gaskets
- ASTM F336 Standard Practice for Design and Construction of Nonmetallic Enveloped Gaskets for Corrosive Service
- Картотека зарубежных и международных стандартов
ASME International
Prevention of Water Damage to Steam Turbines Used for Electric Power Generation: Fossil-Fueled Plants
N TDP-1
Annotation
This Standard includes recommended practices concerned primarily with the prevention of water damage to steam turbines used for fossil-fuel-fired electric power generation. The practices address damage due to water, wet steam, and steam backflow into a steam turbine. The practices are applicable to conventional steam cycle, combined cycle, and cogeneration plants. The practices cover design, operation, inspection, testing, and maintenance of those aspects of the following power plant systems and equipment concerned with preventing the induction of water into steam turbines:
(a) motive steam systems
(b) steam attemperation systems
(c) turbine extraction/admission systems
(d) feedwater heaters
(e) turbine drain system
(f) turbine steam seal system
(g) start-up systems
(h) condenser steam and water dumps
(i) steam generator sources
Any connection to the turbine is a potential source of water either by induction from external equipment or by accumulation of condensed steam. The sources treated herein specifically are those found to be most frequently involved in causing damage to turbines. Althoughwater induction into the high and intermediate pressure turbines has historically been recognized as the most damaging, experience has shown that water induction in low pressure turbines can cause significant damage and should also be taken seriously.