IEC 61000-4-22 Electromagnetic compatibility (EMC) – Part 4-22: Testing and measurement techniques – Radiated emissions and immunity measurements in fully anechoic rooms (FARs) - Edition 1.0
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- IEC TS 60479-1 CORR 1 Effects of current on human beings and livestock – Part 1: General aspects CORRIGENDUM 1 - Edition 4.0
- IEC TR 60479-4 Effects of current on human beings and livestock – Part 4: Effects of lightning strokes - Edition 2.0
- CSA CAN/CSA-E61347-1:03 Lamp controlgear – Part 1: General and safety requirements - First Edition
- 13
- IEC TS 60479-1 CORR 1 Effects of current on human beings and livestock – Part 1: General aspects CORRIGENDUM 1 - Edition 4.0
- 13.200
- IEC TS 60479-1 CORR 1 Effects of current on human beings and livestock – Part 1: General aspects CORRIGENDUM 1 - Edition 4.0
- 29
- IEC TS 60479-1 CORR 1 Effects of current on human beings and livestock – Part 1: General aspects CORRIGENDUM 1 - Edition 4.0
- 29.020
- IEC TS 60479-1 CORR 1 Effects of current on human beings and livestock – Part 1: General aspects CORRIGENDUM 1 - Edition 4.0
- CSA CAN/CSA-E61347-1:03 Lamp controlgear – Part 1: General and safety requirements - First Edition
- IEC TR 60479-4 Effects of current on human beings and livestock – Part 4: Effects of lightning strokes - Edition 2.0
- IEC TS 60479-1 CORR 2 Effects of current on human beings and livestock – Part 1: General aspects CORRIGENDUM 2 - Edition 4.0
- IEC TS 61936-2 Power installations exceeding 1 kV a.c. and 1,5 kV d.c. – Part 2: d.c. - Edition 1.0
- IEC TR 62544 High-voltage direct current (HVDC) systems – Application of active filters - Edition 1.0
- IEC TS 60479-1 CORR 1 Effects of current on human beings and livestock – Part 1: General aspects CORRIGENDUM 1 - Edition 4.0
- Картотека зарубежных и международных стандартов
International Electrotechnical Commission
Electromagnetic compatibility (EMC) – Part 4-22: Testing and measurement techniques – Radiated emissions and immunity measurements in fully anechoic rooms (FARs) - Edition 1.0
N 61000-4-22
Annotation
This part of IEC 61000 considers immunity tests and emission measurements for electric and/or electronic equipment. Only radiated phenomena are considered. It establishes the required test procedures for using fully anechoic rooms for performing radiated immunity testing and radiated emission measurements.
NOTE In accordance with IEC Guide 107 [1], IEC 61000-4-22 is a basic EMC publication for use by product committees of the IEC. As stated in Guide 107, product committees are responsible for determining the applicability of the EMC standards. TC 77 and CISPR and their sub-committees are prepared to cooperate with product committees in the determination of the value of particular EMC tests for specific products.
This part establishes a common validation procedure, equipment under test (EUT) set-up requirements, and measurement methods for fully anechoic rooms (FARs) when both radiated electromagnetic emission measurements and radiated electromagnetic immunity tests will be performed in the same FAR.
As a basic measurement standard, this part of IEC 61000 does not intend to specify the test levels or emission limits to be applied to particular apparatus or system(s). Its main goal is to provide general measurement procedures to all concerned product committees of IEC or CISPR. Specific product requirements and test conditions are defined by the responsible product committees.
The methods described in this standard are appropriate for radiated emission measurements and immunity tests in the frequency range of 30 MHz to 18 GHz.