CSA CAN/CSA-CEI/IEC 61000-4-34-06 AMD 1 Amendment 1 Electromagnetic compatibility (EMC) - Part 4-34: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with mains current more than 16 A per phase - First Edition
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- IEC 60929 AC and/or DC-supplied electronic control gear for tubular fluorescent lamps – Performance requirements - Edition 4.0
- 29
- DIN EN ISO 2858 End-suction centrifugal pumps (rating 16 bar) - Designation, nominal duty point and dimensions (ISO 2858:1975)
- ISO 496 Driving and Driven Machines - Shaft Heights - First Edition
- BSI BS EN 733 End-Suction Centrifugal Pumps, Rating with 10 Bar with Bearing Bracket - Nominal Duty Point, Main Dimensions, Designation System
- BSI DD CLC/TS 50537-3 Railway applications - Mounted parts of the traction transformer and cooling system Part 3: Water pump for traction converters
- BSI BS EN 733 End-Suction Centrifugal Pumps, Rating with 10 Bar with Bearing Bracket - Nominal Duty Point, Main Dimensions, Designation System
- ISO 496 Driving and Driven Machines - Shaft Heights - First Edition
- ISO 496 Driving and Driven Machines - Shaft Heights - First Edition
- BSI BS EN 733 End-Suction Centrifugal Pumps, Rating with 10 Bar with Bearing Bracket - Nominal Duty Point, Main Dimensions, Designation System
- BSI DD CLC/TS 50537-3 Railway applications - Mounted parts of the traction transformer and cooling system Part 3: Water pump for traction converters
- BSI BS EN 733 End-Suction Centrifugal Pumps, Rating with 10 Bar with Bearing Bracket - Nominal Duty Point, Main Dimensions, Designation System
- BSI BS EN 733 End-Suction Centrifugal Pumps, Rating with 10 Bar with Bearing Bracket - Nominal Duty Point, Main Dimensions, Designation System
- BSI DD CLC/TS 50537-3 Railway applications - Mounted parts of the traction transformer and cooling system Part 3: Water pump for traction converters
- BSI DD CLC/TS 50537-3 Railway applications - Mounted parts of the traction transformer and cooling system Part 3: Water pump for traction converters
- BSI BS EN 50533 Railway applications - Three-phase train line voltage characteristics
- BSI BS EN 50160 + A1 Voltage characteristics of electricity supplied by public electricity networks - CORR: March 31, 2011; AMD: July 31, 2015
- IEC TR 61000-2-14 Electromagnetic compatibility (EMC) – Part 2-14: Environment – Overvoltages on public electricity distribution networks - Edition 1.0
- IEC 61000-4-30 Electromagnetic compatibility (EMC) – Part 4-30: Testing and measurement techniques – Power quality measurement methods - Edition 3.0
- Картотека зарубежных и международных стандартов
CSA Standards
Amendment 1 Electromagnetic compatibility (EMC) - Part 4-34: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with mains current more than 16 A per phase - First Edition
N CAN/CSA-CEI/IEC 61000-4-34-06 AMD 1
Annotation
Replace the entire second paragraph of the scope by the following:
This standard applies to electrical and electronic equipment having a rated mains current exceeding 16 A per phase. (See Annex E for guidance on electrical and electronic equipment rated at more than 200 A per phase.) It covers equipment installed in residential areas as well as industrial machinery, specifically voltage dips and short interruptions for equipment connected to either 50 Hz or 60 Hz a.c. networks, including 1-phase and 3-phase mains.
NOTE 1 Equipment with a rated mains current of 16 A or less per phase is covered by publication IEC 61000-4-11.
NOTE 2 There is no upper limit on rated mains current in this publication. However, in some countries, the rated mains current may be limited to some upper value, for example 75 A or 250 A, because of mandatory safety standards.
Автоматический перевод:
Электромагнитная совместимость поправки 1 (EMC) - Часть 4-34: Тестирование и техники измерений - падения Напряжения, короткие прерывания и испытания на невосприимчивость изменений напряжения для оборудования с электросетью текущие больше чем 16 А на фазу - Первый Выпуск