IEC 60079-30-1 Explosive atmospheres – Part 30-1: Electrical resistance trace heating – General and testing requirements - Edition 1.0
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- IEC 60079-11 CORR 1 Explosive atmospheres – Part 11: Equipment protection by intrinsic safety “I” - Edition 6.0
- BSI BS EN 60079-6 Explosive atmospheres - Part 6: Equipment protection by oil immersion “o” - AMD: June 30, 2008
- BSI BS EN 13922 Tanks for transport of dangerous goods - Service equipment for tanks - Overfill prevention systems for liquid fuels
- BSI BS EN 60079-6 Explosive atmospheres - Part 6: Equipment protection by oil immersion “o” - AMD: June 30, 2008
- 29
- IEC 60079-11 CORR 1 Explosive atmospheres – Part 11: Equipment protection by intrinsic safety “I” - Edition 6.0
- BSI BS EN 60079-6 Explosive atmospheres - Part 6: Equipment protection by oil immersion “o” - AMD: June 30, 2008
- BSI BS EN 13922 Tanks for transport of dangerous goods - Service equipment for tanks - Overfill prevention systems for liquid fuels
- BSI BS EN 60079-6 Explosive atmospheres - Part 6: Equipment protection by oil immersion “o” - AMD: June 30, 2008
- 29.260
- IEC 60079-11 CORR 1 Explosive atmospheres – Part 11: Equipment protection by intrinsic safety “I” - Edition 6.0
- BSI BS EN 60079-6 Explosive atmospheres - Part 6: Equipment protection by oil immersion “o” - AMD: June 30, 2008
- BSI BS EN 13922 Tanks for transport of dangerous goods - Service equipment for tanks - Overfill prevention systems for liquid fuels
- BSI BS EN 60079-6 Explosive atmospheres - Part 6: Equipment protection by oil immersion “o” - AMD: June 30, 2008
- 29.260.20
- IEC 60079-11 CORR 1 Explosive atmospheres – Part 11: Equipment protection by intrinsic safety “I” - Edition 6.0
- BSI BS EN 60079-6 Explosive atmospheres - Part 6: Equipment protection by oil immersion “o” - AMD: June 30, 2008
- BSI BS EN 13922 Tanks for transport of dangerous goods - Service equipment for tanks - Overfill prevention systems for liquid fuels
- BSI BS EN 60079-6 Explosive atmospheres - Part 6: Equipment protection by oil immersion “o” - AMD: June 30, 2008
- IEC 60079-11 CORR 1 Explosive atmospheres – Part 11: Equipment protection by intrinsic safety “I” - Edition 6.0
- IEC 60079-11 CORR 1 Explosive atmospheres – Part 11: Equipment protection by intrinsic safety “I” - Edition 6.0
- IEC 60079-11 CORR 1 Explosive atmospheres – Part 11: Equipment protection by intrinsic safety “I” - Edition 6.0
- CENELEC EN 60079-2 Explosive atmospheres - Part 2: Equipment protection by pressurized enclosure "p"
- IEC 60079-15 Explosive atmospheres – Part 15: Equipment protection by type of protection "n" - Edition 4.0
- BSI BS EN 60079-6 Explosive atmospheres - Part 6: Equipment protection by oil immersion “o” - AMD: June 30, 2008
- BSI BS EN 13922 Tanks for transport of dangerous goods - Service equipment for tanks - Overfill prevention systems for liquid fuels
- BSI BS EN 60079-6 Explosive atmospheres - Part 6: Equipment protection by oil immersion “o” - AMD: June 30, 2008
- IEC 60079-15 Explosive atmospheres – Part 15: Equipment protection by type of protection "n" - Edition 4.0
- BSI BS EN 60079-6 Explosive atmospheres - Part 6: Equipment protection by oil immersion “o” - AMD: June 30, 2008
- BSI BS EN 13922 Tanks for transport of dangerous goods - Service equipment for tanks - Overfill prevention systems for liquid fuels
- BSI BS EN 13922 Tanks for transport of dangerous goods - Service equipment for tanks - Overfill prevention systems for liquid fuels
- BSI BS EN 60079-10-1 Explosive atmospheres - Part 10-1: Classification of areas - Explosive gas atmospheres
- IEC 60079-11 CORR 1 Explosive atmospheres – Part 11: Equipment protection by intrinsic safety “I” - Edition 6.0
- Картотека зарубежных и международных стандартов
International Electrotechnical Commission
Explosive atmospheres – Part 30-1: Electrical resistance trace heating – General and testing requirements - Edition 1.0
N 60079-30-1
Annotation
This part of IEC 60079 specifies general and testing requirements for electrical resistance trace heaters for application in explosive gas atmospheres. The standard covers trace heaters that may comprise either factory- or field- (work-site) assembled units, and which may be series heating cables, parallel heating cables or heating pads and heating panels that have been assembled and/or terminated in accordance with the manufacturer's instructions.
This standard also includes requirements for termination assemblies and control methods used with trace heating. The hazardous areas referred to by this standard are those defined in IEC 60079-10.
Where a requirement of this standard conflicts with a requirement of IEC 60079-0, the requirement of this standard shall take precedence.
Автоматический перевод:
Взрывоопасные атмосферы – Часть 30-1: Электрическое нагревание следа сопротивления – Общие и проверяющие требования - Издание 1.0
Эта часть IEC 60079 указывает общие и тестирующие требования для электрических нагревателей трассировки сопротивления для приложения во взрывчатых газовых атмосферах. Стандарт касается нагревателей трассировки, которые могут включить или фабрику - или поле - собранные модули (рабочего места), и которые могут быть серийными обогревающими кабелями, параллельными обогревающими кабелями или электрогрелками и нагреванием панелей, которые были собраны и/или завершены в соответствии с инструкциями производителя.