CENELEC EN 50182 Conductors for overhead lines - Round wire concentric lay stranded conductors - Incorporating corrigendum July 2013
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- IEC TS 60479-1 CORR 1 Effects of current on human beings and livestock – Part 1: General aspects CORRIGENDUM 1 - Edition 4.0
- 13
- IEC TS 60479-1 CORR 1 Effects of current on human beings and livestock – Part 1: General aspects CORRIGENDUM 1 - Edition 4.0
- 13.200
- IEC TS 60479-1 CORR 1 Effects of current on human beings and livestock – Part 1: General aspects CORRIGENDUM 1 - Edition 4.0
- 29
- IEC TS 60479-1 CORR 1 Effects of current on human beings and livestock – Part 1: General aspects CORRIGENDUM 1 - Edition 4.0
- 29.020
- IEC TS 60479-1 CORR 1 Effects of current on human beings and livestock – Part 1: General aspects CORRIGENDUM 1 - Edition 4.0
- IEC 60287-1-2 Electric Cables - Calculation of the Current Rating - Part 1: Current Rating Equations (100% Load Factor) and Calculation of Losses - Section 2: Sheath Eddy Current Loss Factors for Two Circuits in Flat Formation - Edition 1.0
- BSI BS IEC 60287-1-1 + A1 Electric cables - Calculation of the current rating - Part 1-1: Current rating equations (100% load factor) and calculation of losses - General - AMD: November 30, 2014
- IEC 60889 Hard-Drawn Aluminium Wire for Overhead Line Conductors - Edition 1.0
- BSI BS IEC 60287-1-1 + A1 Electric cables - Calculation of the current rating - Part 1-1: Current rating equations (100% load factor) and calculation of losses - General - AMD: November 30, 2014
- BSI BS IEC 60287-1-1 + A1 Electric cables - Calculation of the current rating - Part 1-1: Current rating equations (100% load factor) and calculation of losses - General - AMD: November 30, 2014
- IEC 60889 Hard-Drawn Aluminium Wire for Overhead Line Conductors - Edition 1.0
- IEC 60889 Hard-Drawn Aluminium Wire for Overhead Line Conductors - Edition 1.0
- CENELEC EN 50341-1 Overhead electrical lines exceeding AC 1 kV - Part 1: General requirements - Common specifications
- CENELEC EN 60433 Insulators for Overhead Lines with a Nominal Voltage Above 1 kv Ceramic Insulators for a.c. Systems Characteristics of Insulator Units of the Long Rod Type
- CENELEC EN 60889 Hard-Drawn Aluminium Wire for Overhead Line Conductors
- Картотека зарубежных и международных стандартов
European Committee for Electrotechnical Standardization
Conductors for overhead lines - Round wire concentric lay stranded conductors - Incorporating corrigendum July 2013
N EN 50182
Annotation
This European Standard specifies the electrical and mechanical characteristics of round wire concentric lay bare overhead electrical conductors stranded in alternate directions, with or without grease as per EN 50326, made of one or a combination of any of the following:
a) Hard drawn Aluminium as per EN 60889 designated AL1
b) Aluminium alloy as per EN 50183 designated AL2 TO AL7
c) Zinc coated steel wire as per EN 50189 with grade and class designated ST1A, ST2B, ST3D, ST4A, ST5E, and ST6C.
d) Aluminium-cald steel wire as per EN 61232 with class designation 20SA (grades A and B), 27SA, 30SA and 40SA.
Conductors made of zinc coated steel wires only are not included.
Автоматический перевод:
Проводники для верхних линий - Раунд соединяет проводом концентрический, кладут скрученные проводники - Соединяющийся июль 2013 исправления
Этот европейский стандарт определяет, что электрические и механические характеристики круглого концентрического провода раскрывают верхние электрические проводники, скрученные в альтернативных направлениях, с или без смазки согласно EN 50326, сделанному из одного или комбинации любого следующего: