IEC 61109 Insulators for overhead lines – Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1 000 V – Definitions, test methods and acceptance criteria - Edition 2.0
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- CENELEC EN 50423-3 Overhead electrical lines exceeding AC 1 kV up to and including AC 45 kV Part 3: Set of National Normative Aspects - Incorporating Corrigenda April 2005, February 2009, June 2010 and October 2010
- 29
- CENELEC EN 50423-3 Overhead electrical lines exceeding AC 1 kV up to and including AC 45 kV Part 3: Set of National Normative Aspects - Incorporating Corrigenda April 2005, February 2009, June 2010 and October 2010
- 29.240
- BSI BS EN 45545-2 Railway applications - Fire protection on railway vehicles Part 2: Requirements for fire behaviour of materials and components
- CEN EN ISO 9239-1 Reaction to fire tests for floorings - Part 1: Determination of the burning behaviour using a radiant heat source
- BSI PD CEN/TR 14819-1 Safety recommendations for cableway installations designed to carry persons Prevention and fight against fire Part 1: Funicular railways in tunnels
- BSI BS EN 13501-2 + A1 Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services - AMD: November 30, 2009
- BSI PD CEN/TR 14819-1 Safety recommendations for cableway installations designed to carry persons Prevention and fight against fire Part 1: Funicular railways in tunnels
- CEN EN ISO 9239-1 Reaction to fire tests for floorings - Part 1: Determination of the burning behaviour using a radiant heat source
- CEN EN ISO 9239-1 Reaction to fire tests for floorings - Part 1: Determination of the burning behaviour using a radiant heat source
- BSI PD CEN/TR 14819-1 Safety recommendations for cableway installations designed to carry persons Prevention and fight against fire Part 1: Funicular railways in tunnels
- BSI BS EN 13501-2 + A1 Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services - AMD: November 30, 2009
- BSI PD CEN/TR 14819-1 Safety recommendations for cableway installations designed to carry persons Prevention and fight against fire Part 1: Funicular railways in tunnels
- BSI PD CEN/TR 14819-1 Safety recommendations for cableway installations designed to carry persons Prevention and fight against fire Part 1: Funicular railways in tunnels
- BSI BS EN 13501-2 + A1 Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services - AMD: November 30, 2009
- BSI BS EN 13501-2 + A1 Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services - AMD: November 30, 2009
- BSI PD CEN/TR 14819-2 Safety recommendations for cableway installations designed to carry persons Prevention and fight against fire Part 2: Other funicular railways and other installations
- BSI BS EN 50119 + A1 Railway applications - Fixed installations - Electric traction overhead contact lines - AMD: May 31, 2013
- BSI BS EN 50151 Railway applications - Fixed installations - Electric traction - Special requirements for composite insulators - CORR: August 31, 2010
- Картотека зарубежных и международных стандартов
International Electrotechnical Commission
Insulators for overhead lines – Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1 000 V – Definitions, test methods and acceptance criteria - Edition 2.0
N 61109
Annotation
This International Standard is applicable to composite insulators for use as suspension/tension line insulators, but it is to be noted that these insulators can occasionally be subjected to compression or bending, for example when used as phase-spacers. Composite insulators designed primarily to resist bending loads, e.g. line post insulators, are not included in the scope of this Standard.
This standard deals with those composite insulators which include a "core" and a "housing". The core is usually made of resin-impregnated glass fibres. The housing can be manufactured from a variety of materials including elastomers (e.g. silicone, ethylene-propylene); resins (e.g. cycloaliphatic epoxy); or fluorocarbons (e.g. polytetrafluoroethylene).
The object of this Standard is to:
- define the terms used;
- prescribe test methods;
- prescribe acceptance criteria.
This standard does not include requirements dealing with the choice of insulators for specific operating conditions.
Автоматический перевод:
Изоляторы для верхних линий – Сложной приостановки и изоляторов силы для a.c. систем с номинальным напряжением, больше, чем 1 000 В – Определения, методы испытаний и критерии допустимости - Издание 2.0