CENELEC EN 61210 Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- IEC 60335-1 Household and similar electrical appliances . Safety . Part 1: General requirements - Edition 5.1 Consolidated Reprint
- 13
- 97
- IEC TR 60479-4 Effects of current on human beings and livestock – Part 4: Effects of lightning strokes - Edition 2.0
- IEC TS 60479-1 CORR 2 Effects of current on human beings and livestock – Part 1: General aspects CORRIGENDUM 2 - Edition 4.0
- IEC 61230 Live working – Portable equipment for earthing or earthing and short-circuiting - Edition 2.0
- IEC TS 60479-1 CORR 2 Effects of current on human beings and livestock – Part 1: General aspects CORRIGENDUM 2 - Edition 4.0
- IEC TS 60479-1 CORR 2 Effects of current on human beings and livestock – Part 1: General aspects CORRIGENDUM 2 - Edition 4.0
- IEC 61230 Live working – Portable equipment for earthing or earthing and short-circuiting - Edition 2.0
- IEC 61230 Live working – Portable equipment for earthing or earthing and short-circuiting - Edition 2.0
- BSI BS EN 175301-803 Detail Specification: Rectangular connectors Flat contacts, 0,8 mm thickness, locking screw not detachable
- BSI BS EN 16304 Automatic vent valves for gas burners and gas burning appliances
- Картотека зарубежных и международных стандартов
European Committee for Electrotechnical Standardization
Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements
N EN 61210
Annotation
This International Standard applies to non-insulated flat quick-connect terminations consisting of a male tab of size 2,8 mm, 4,8 mm, 6,3 mm or 9,5 mm with hole or dimple detents and a mating female connector for use as either an incorporated or an integrated part of an equipment or of a component, or as a separate entity. This standard establishes uniform requirements for the dimensions, performance characteristics and test program.
The connected electrical copper conductors shall be flexible or rigid stranded, having a crosssectional area up to and including 6 mm2 or rigid solid having a cross-sectional area up to and including 2,5 mm2. This standard shall not be used for connecting aluminum conductors.
The rated voltage shall not exceed 1 000 V a.c. with a frequency up to and including 1 000 Hz, and 1 500 V d.c., and having the temperature limits applicable to materials used within this standard.
NOTE 1 This standard, where applicable, may be used for conductors made of material other than copper.
NOTE 2 For reasons of safety, it is recommended that flat quick-connect terminations beyond the scope of this standard should not be interchangeable with those of this standard.
NOTE 3 This standard does not apply to female connectors with positive locking means.
NOTE 4 The flat quick-connect terminations covered by this standard are not intended to be disconnected by pulling on the cable.
NOTE 5 Annex D provides additional information on non international units.