IEC 60570 Electrical supply track systems for luminaires - Edition 4.0
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- IEC 61084-1 Cable Trunking and Ducting Systems for Electrical Installations Part 1: General Requirements - Edition 1.0
- 29
- IEC 60335-2-9 Household and similar electrical appliances – Safety – Part 2-9: Particular requirements for grills, toasters and similar portable cooking appliances - Edition 6.1 Consolidated Reprint
- IEC 60335-2-12 Household and similar electrical appliances – Safety – Part 2-12: Particular requirements for warming plates and similar appliances - Edition 5.1 Consolidated Reprint
- IEC 60695-10-2 Fire hazard testing – Part 10-2: Abnormal heat – Ball pressure test method - Edition 3.0
- IEC 60335-2-12 Household and similar electrical appliances – Safety – Part 2-12: Particular requirements for warming plates and similar appliances - Edition 5.1 Consolidated Reprint
- IEC 60335-2-12 Household and similar electrical appliances – Safety – Part 2-12: Particular requirements for warming plates and similar appliances - Edition 5.1 Consolidated Reprint
- IEC 60695-10-2 Fire hazard testing – Part 10-2: Abnormal heat – Ball pressure test method - Edition 3.0
- IEC 61534-1 Powertrack systems – Part 1: General requirements - Edition 2.1 Consolidated Reprint
- IEC 61084-2-4 Cable Trunking and Ducting Systems for Electrical Installations - Part 2: Particular Requirements - Section 4: Service Poles - Edition 1.0
- CENELEC EN 61439-6 Low-voltage switchgear and controlgear assemblies - Part 6: Busbar trunking systems (busways)
- IEC 60570 Electrical supply track systems for luminaires - Edition 4.0
- CEI EN 61439-6 Low-voltage switchgear and controlgear assemblies Part 6: Busbar trunking systems (busways)
- Картотека зарубежных и международных стандартов
International Electrotechnical Commission
Electrical supply track systems for luminaires - Edition 4.0
N 60570
Annotation
This International Standard applies to the following track systems with two or more poles for the connection of luminaires to the electrical supply consisting of, either
– a system with a rated voltage not exceeding 440 V between poles (live conductors) with provision for earthing (class I) and a rated current not exceeding 16 A per conductor, or
– a SELV system with a rated voltage not exceeding 25 V without provision for earthing (class III) and a rated current not exceeding 25 A per conductor, or
– a combination of the two systems mentioned above (mixed supply system) for the connection of both mains voltage luminaires (class I or II) and SELV supplied luminaires (class III) simultaneously, but in different sector openings (mains or SELV).
The track systems may also provide for the mechanical support of the luminaires.
It applies to track systems designed for ordinary interior use for mounting on, or flush with, or suspended from walls and ceilings. These track systems are not intended for locations where special conditions prevail as in ships, vehicles and the like and in hazardous locations, for example, where explosions are liable to occur.