IEC 60691 Thermal-links – Requirements and application guide - Edition 3.2 Consolidated Reprint
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- IEC 60335-1 Household and similar electrical appliances . Safety . Part 1: General requirements - Edition 5.1 Consolidated Reprint
- 13
- 97
- IEC TR 60479-4 Effects of current on human beings and livestock – Part 4: Effects of lightning strokes - Edition 2.0
- IEC TS 60479-1 CORR 2 Effects of current on human beings and livestock – Part 1: General aspects CORRIGENDUM 2 - Edition 4.0
- IEC 61230 Live working – Portable equipment for earthing or earthing and short-circuiting - Edition 2.0
- IEC TS 60479-1 CORR 2 Effects of current on human beings and livestock – Part 1: General aspects CORRIGENDUM 2 - Edition 4.0
- IEC TS 60479-1 CORR 2 Effects of current on human beings and livestock – Part 1: General aspects CORRIGENDUM 2 - Edition 4.0
- IEC 61230 Live working – Portable equipment for earthing or earthing and short-circuiting - Edition 2.0
- IEC 61230 Live working – Portable equipment for earthing or earthing and short-circuiting - Edition 2.0
- BSI BS EN 175301-803 Detail Specification: Rectangular connectors Flat contacts, 0,8 mm thickness, locking screw not detachable
- BSI BS EN 16304 Automatic vent valves for gas burners and gas burning appliances
- Картотека зарубежных и международных стандартов
International Electrotechnical Commission
Thermal-links – Requirements and application guide - Edition 3.2 Consolidated Reprint
N 60691
Annotation
This International Standard is applicable to thermal-links intended for incorporation in electrical appliances, electronic equipment and component parts thereof, normally intended for use indoors, in order to protect them against excessive temperatures under abnormal conditions.
NOTE 1 The equipment need not be designed to generate heat.
NOTE 2 The effectiveness of the protection against excessive temperatures logically depends upon the position and method of mounting of the thermal-link, as well as upon the current which it is carrying.
NOTE 3 Attention is drawn to the fact that the external creepage distances and clearances specified in Table 3 may in some cases be smaller than those required by certain appliance or equipment standards. In such cases, additional means should be provided when a thermal-link is mounted in the equipment in order to adjust the creepage distances and clearances to the values required by the relevant equipment standard.
This standard may be applicable to thermal-links for use under conditions other than indoors, provided that the climatic and other circumstances in the immediate surroundings of such thermal-links are comparable with those in this standard.
This standard may be applicable to thermal-links in their simplest forms (e.g. melting strips or wires), provided that molten materials expelled during function cannot adversely interfere with the safe use of the equipment, especially in the case of hand-held or portable equipment, irrespective of its position.
This standard is applicable to thermal-links with a rated voltage not exceeding 690 V a.c. or d.c. and a rated current not exceeding 63 A.