CEI EN 60947-5-3 Low-voltage switchgear and controlgear Part 5-3: Control circuit devices and switching elements - Requirements for proximity devices with defined behaviour under fault conditions (PDDB)
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ISO 13849-1 Safety of machinery Safety-related parts of control systems Part 1: General principles for design - Second Edition
- 13
- ISO 13849-1 Safety of machinery Safety-related parts of control systems Part 1: General principles for design - Second Edition
- 13.110
- CENELEC CLC/TR 62685 Industrial communication networks - Profiles - Assessment guideline for safety devices using IEC 61784-3 functional safety communication profiles (FSCPs)
- ISO 13849-1 CORR 1 Safety of machinery — Safety-related parts of control systems — Part 1: General principles for design TECHNICAL CORRIGENDUM 1 - Second Edition
- 13.160
- CENELEC CLC/TR 62685 Industrial communication networks - Profiles - Assessment guideline for safety devices using IEC 61784-3 functional safety communication profiles (FSCPs)
- ISO 13849-1 CORR 1 Safety of machinery — Safety-related parts of control systems — Part 1: General principles for design TECHNICAL CORRIGENDUM 1 - Second Edition
- CENELEC CLC/TR 62685 Industrial communication networks - Profiles - Assessment guideline for safety devices using IEC 61784-3 functional safety communication profiles (FSCPs)
- CENELEC CLC/TR 62685 Industrial communication networks - Profiles - Assessment guideline for safety devices using IEC 61784-3 functional safety communication profiles (FSCPs)
- ISO 13849-1 CORR 1 Safety of machinery — Safety-related parts of control systems — Part 1: General principles for design TECHNICAL CORRIGENDUM 1 - Second Edition
- 35
- CENELEC CLC/TR 62685 Industrial communication networks - Profiles - Assessment guideline for safety devices using IEC 61784-3 functional safety communication profiles (FSCPs)
- ISO 13849-1 CORR 1 Safety of machinery — Safety-related parts of control systems — Part 1: General principles for design TECHNICAL CORRIGENDUM 1 - Second Edition
- CENELEC CLC/TR 62685 Industrial communication networks - Profiles - Assessment guideline for safety devices using IEC 61784-3 functional safety communication profiles (FSCPs)
- ISO 13849-1 CORR 1 Safety of machinery — Safety-related parts of control systems — Part 1: General principles for design TECHNICAL CORRIGENDUM 1 - Second Edition
- ISO 13856-3 Safety of machinery - Pressuresensitive protective devices - Part 3: General principles for design and testing of pressure-sensitive bumpers, plates, wires and similar devices - Second Edition
- IEC 61496-3 Safety of machinery – Electro-sensitive protective equipment – Part 3: Particular requirements for Active Opto-electronic Protective Devices responsive to Diffuse Reflection (AOPDDR) - Edition 2.0
- Картотека зарубежных и международных стандартов
Comitato Elettrotecnico Italiano
Low-voltage switchgear and controlgear Part 5-3: Control circuit devices and switching elements - Requirements for proximity devices with defined behaviour under fault conditions (PDDB)
N EN 60947-5-3
Annotation
This part of IEC 60947 series provides additional requirements to those given in IEC 60947-5-2. It addresses the fault performance aspects of proximity devices with a defined behaviour under fault conditions (PDDB). It does not address any other characteristics that can be required for specific applications.
This standard does not cover proximity devices with analogue output.
This Standard does not deal with any specific requirements on acoustic noise as the noise emission of control circuit devices and switching elements is not considered to be a relevant hazard.
For a PDDB used in applications where additional characteristics, dealt with in other standards, are required, the requirements of all relevant standards apply.
The use of this standard alone does not demonstrate suitability for the implementation of any specific safety related functionality. In particular, this standard does not provide requirements for the actuation characteristics of a PDDB, or for means to reduce the effects of mutual interference between devices, e.g. coded targets. Therefore these and any other applicationspecific requirements will need to be considered in addition to the requirements of this standard.
NOTE 1 Due to their behaviour under fault conditions, PDDBs can, for example, be used as interlocking devices (see ISO 14119).
NOTE 2 The requirements for electro-sensitive protective equipment for the detection of persons are given in the IEC 61496 series.