ASTM F2767 Standard Specification for Electrofusion Type Polyamide-12 Fittings for Outside Diameter Controlled Polyamide-12 Pipe and Tubing for Gas Distribution
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM G125 Standard Test Method for Measuring Liquid and Solid Material Fire Limits in Gaseous Oxidants
- 13
- ASTM G125 Standard Test Method for Measuring Liquid and Solid Material Fire Limits in Gaseous Oxidants
- 13.220
- ASTM G125 Standard Test Method for Measuring Liquid and Solid Material Fire Limits in Gaseous Oxidants
- 13.220.40
- ASTM G125 Standard Test Method for Measuring Liquid and Solid Material Fire Limits in Gaseous Oxidants
- 19
- ASTM G125 Standard Test Method for Measuring Liquid and Solid Material Fire Limits in Gaseous Oxidants
- ASTM F2390 Standard Specification for Poly(Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent (DWV) Pipe and Fittings Having Post-Industrial Recycle Content
- ASTM F480 Standard Specification for Thermoplastic Well Casing Pipe and Couplings Made in Standard Dimension Ratios (SDR), SCH 40 and SCH 80
- ASTM D2122 Standard Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings
- Картотека зарубежных и международных стандартов
ASTM International
Standard Specification for Electrofusion Type Polyamide-12 Fittings for Outside Diameter Controlled Polyamide-12 Pipe and Tubing for Gas Distribution
N F2767
Annotation
This specification covers polyamide- 12 electrofusion fittings for use with outside diameter-controlled polyamide- 12 pipe, covered by Specification F2785. Requirements for materials, workmanship, and testing performance are included. Where applicable in this specification "pipe" shall mean "pipe" or "tubing."
Polyamide 12 electrofusion fittings are intended for use in polyamide 12 systems only. As per the manufacturer's recommendations, no cross fusion between PA12, PA11 and PE is permitted.
The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
The following safety hazards caveat pertains only to the test method portion, Section 9, of this specification:This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
*A Summary of Changes section appears at the end of this standard
Автоматический перевод:
Стандартная спецификация для полиамида типа электрослияния 12 деталей для наружного диаметра управляемый полиамид 12 труб и трубка для газоснабжения