ASTM D5659 Standard Test Method for Chlorophenoxy Acid Herbicides in Waste Using HPLC
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM D7202 Standard Test Method for Determination of Beryllium in the Workplace by Extraction and Optical Fluorescence Detection
- 13
- ASTM E4 Standard Practices for Force Verification of Testing Machines
- ASTM E855 Standard Test Methods for Bend Testing of Metallic Flat Materials for Spring Applications Involving Static Loading
- ASTM E691 Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method
- ASTM E855 Standard Test Methods for Bend Testing of Metallic Flat Materials for Spring Applications Involving Static Loading
- ASTM E855 Standard Test Methods for Bend Testing of Metallic Flat Materials for Spring Applications Involving Static Loading
- ASTM E691 Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method
- ASTM E691 Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method
- ASTM E70 Standard Test Method for pH of Aqueous Solutions With the Glass Electrode
- ULC CAN/ULC-S563-06 STANDARD FOR CATEGORY 3 FILM-FORMING FLUOROPROTEIN (FFFP) FOAM LIQUID CONCENTRATES - Second Edition
- ULC ULC-S564-06 STANDARD FOR CATEGORIES 1 AND 2 FOAM LIQUID CONCENTRATES - Second Edition
- ULC CAN/ULC-S560-06 STANDARD FOR CATEGORY 3 AQUEOUS FILM-FORMING FOAM (AFFF) LIQUID CONCENTRATES - Second Edition
- Картотека зарубежных и международных стандартов
ASTM International
Standard Test Method for Chlorophenoxy Acid Herbicides in Waste Using HPLC
N D5659
Annotation
This test method covers the analysis of 2,4- dichlorophenoxyacetic acid (2,4-D), 2,4,5- trichlorophenoxyacetic acid (2,4,5-T), and 2,4,5- trichlorophenoxypropionic acid (silvex) in liquids and solids, using high performance liquid chromatography with an ultraviolet detector (HPLC/UV). This test method is applicable for a concentration range from approximately 50 to 1000 ppm. This range takes into consideration the sample preparation and dilutions outlined in Section 10. Lower detection levels can be obtained by using larger sample sizes, smaller total final volumes, or with the use of in-line or solid phase extraction, concentration, or cleanup, or combinations thereof.
The chlorophenoxy herbicides may be present as a variety of salts or esters, which are converted to, analyzed, and reported as their respective acids.
This test method is applicable to liquid and solid waste and waste extract matrices including aqueous, oil, spent solvent, soil, ash, leachates, etc.
This test method may be applicable to other phenoxy acid herbicides.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. See Section 7 and 10.3.1 for specific precautionary statements.
Автоматический перевод:



