ISO 7890-3 Water Quality - Determination of Nitrate - Part 3: Spectrometric Method Using Sulfosalicylic Acid First Edition
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ISO 14255 Soil Quality - Determination of Nitrate Nitrogen, Ammonium Nitrogen and Total Soluble Nitrogen in Air-Dry Soils Using Calcium Chloride Solution as Extractant - First Edition
- 13
- ISO 14255 Soil Quality - Determination of Nitrate Nitrogen, Ammonium Nitrogen and Total Soluble Nitrogen in Air-Dry Soils Using Calcium Chloride Solution as Extractant - First Edition
- 13.080
- ISO 14255 Soil Quality - Determination of Nitrate Nitrogen, Ammonium Nitrogen and Total Soluble Nitrogen in Air-Dry Soils Using Calcium Chloride Solution as Extractant - First Edition
- 13.080.10
- SNV SN EN ISO 15175 Soil quality - Characterization of soil related to groundwater protection
- SNV SN EN ISO 15175 Soil quality - Characterization of soil related to groundwater protection
- SNV SN EN ISO 15175 Soil quality - Characterization of soil related to groundwater protection
- BSI BS EN ISO 15175 Soil quality - Characterization of soil related to groundwater protection - CORR: August 31, 2011
- Картотека зарубежных и международных стандартов
International Organization for Standardization
Water Quality - Determination of Nitrate - Part 3: Spectrometric Method Using Sulfosalicylic Acid First Edition
N 7890-3
Annotation
Substance determined
This part of IS0 7890 specifies a method for the determination of nitrate ion in water.
Type of sample
The method is suitable for application to raw and potable water samples.
Range
Up to a nitrate nitrogen concentration, @N of O,2 mg/l using the maximum test portion volume of 25 ml. The range can be extended upwards by taking smaller test portions.
Limit of detectionl)
Using cells of optical path length 40 mm and a 25 ml test portion volume the limit of detection lies within the range @N = 0,003 to 0,013 mg/l.
Sensitivity')
A nitrate nitrogen concentration of @N = 0,2 mg/l gives an absorbance of about 0,68 unit, using a 25 ml test portion and cells of optical path length 40 mm.
Interferences
A range of substances often encountered in water samples has been tested for possible intetference with this method. Full details are given in annex A. The main potential interferents are chloride, orthophosphate, magnesium and manganese(ll), as shown in annex A.
Other tests have shown that this method will tolerate a sample colour of up to 150 mg/l Pt providing the test portion absorption correction procedure is followed. (See 6.5.)