JSA JIS B 9704-3 Safety of machinery - Electro-sensitive protective equipment - Part 3: Particular requirements for Active Opto-electronic Protective Devices responsive to Diffuse Reflection (AOPDDR)
Данный раздел/документ содержится в продуктах:
Japanese Standards Association
Safety of machinery - Electro-sensitive protective equipment - Part 3: Particular requirements for Active Opto-electronic Protective Devices responsive to Diffuse Reflection (AOPDDR)
N JIS B 9704-3
Annotation
Replacement:
This Standard specifies additional requirements for the design, construction and testing of non-contact electro-sensitive protective equipment (ESPE) designed specifically to detect persons as part of a safety related system, employing active opto-electronic protective devices responsive to diffuse reflection (AOPDDRs) for the sensing function. Special attention is directed to requirements which ensure that an appropriate safety-related performance is achieved. An ESPE may include optional safetyrelated functions, the requirements for which are given both in Annex A of this Standard and in Annex A of part 1.
This Standard does not specify the dimensions or configurations of the detection zone and its disposition in relation to hazardous parts for any particular application, nor what constitutes a hazardous state of any machine. It is restricted to the functioning of the ESPE and how it interfaces with the machine.
AOPDDRs are devices that have a detection zone specified in two dimensions wherein radiation in the near infrared range is emitted by a transmitter element(s). When the emitted radiation impinges on an object (for example, a person or part of a person), a portion of the emitted radiation is reflected to a receiving element(s) by diffuse reflection whereby the presence of the object can be detected.
NOTE 1 Under certain circumstances, limitations of the sensor in relation to its use need to be considered. For example:
— Objects that generate mirror-like (specular) reflections may not be detected if the diffuse reflectance value is less than that specified for the "black" test piece.