CENELEC EN 50355 Railway applications - Railway rolling stock cables having special fire performance - Guide to use
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- BSI BS EN 45545-2 Railway applications - Fire protection on railway vehicles Part 2: Requirements for fire behaviour of materials and components
- 13
- BSI BS EN 45545-2 Railway applications - Fire protection on railway vehicles Part 2: Requirements for fire behaviour of materials and components
- 13.220
- BSI BS EN 45545-2 Railway applications - Fire protection on railway vehicles Part 2: Requirements for fire behaviour of materials and components
- 13.220.20
- BSI BS EN 45545-2 Railway applications - Fire protection on railway vehicles Part 2: Requirements for fire behaviour of materials and components
- 45
- BSI BS EN 45545-2 Railway applications - Fire protection on railway vehicles Part 2: Requirements for fire behaviour of materials and components
- 45.060
- BSI BS EN 45545-2 Railway applications - Fire protection on railway vehicles Part 2: Requirements for fire behaviour of materials and components
- CEN EN ISO 9239-1 Reaction to fire tests for floorings - Part 1: Determination of the burning behaviour using a radiant heat source
- DIN EN 45545-2 Railway applications - Fire protection on railway vehicles - Part 2: Requirements for fire behaviour of materials and components
- CENELEC EN 50306-4 Railway applications Railway rolling stock cables having special fire performance Thin wall Part 4: Multicore and multipair cables standard wall sheathed
- Картотека зарубежных и международных стандартов
European Committee for Electrotechnical Standardization
Railway applications - Railway rolling stock cables having special fire performance - Guide to use
N EN 50355
Annotation
This European Standard gives guidance on the safe use of rolling stock cables specified in EN 50264, EN 50306 and EN 50382.These cables will only be used for the wiring of railway rolling stock and within the limits given in the manner described in this European Standard. All these cables are for fixed installation where there is no free movement of cable, except for stresses due to typical service.
This European Standard will be applied in conjunction with the relevant product and installation standards. Stricter requirements than those given in this standard could be necessary; see in particular EN 50343.
This European Standard is not applicable to:
- intercarriage jumpers;
- cables subject to continual flexing;
- pantograph cables;
-coaxial, data and fibre optic cables;
- wire wrap;
- cables rated at voltages greater than 3,6/6 kV;
- applications other than the cabling of railway rolling stock;
- cables requiring circuit integrity.
Legal or statutory requirements do take precedence over the guidance given in this document.
In cases where no guidance exists or where it cannot be derived from general information, it is recommended that advice be sought from the cable manufacturer.