DIN EN 12341 Ambient air - Standard gravimetric measurement method for the determination of the PM10 or PM2,5 mass concentration of suspended particulate matter; German version EN 12341:2014
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- VDI 2267 BLATT 3 Determination of suspended matter in ambient air - Digestion variants for dust samples for the subsequent determination of the mass concentration of Al, Sb, As, Pb, Cd, Ca, Cr, Co, Fe, K, Cu, Mg, Mn, Na, Ni, Se, V and Zn
- 13
- VDI 2267 BLATT 3 Determination of suspended matter in ambient air - Digestion variants for dust samples for the subsequent determination of the mass concentration of Al, Sb, As, Pb, Cd, Ca, Cr, Co, Fe, K, Cu, Mg, Mn, Na, Ni, Se, V and Zn
- 13.040
- VDI 2267 BLATT 3 Determination of suspended matter in ambient air - Digestion variants for dust samples for the subsequent determination of the mass concentration of Al, Sb, As, Pb, Cd, Ca, Cr, Co, Fe, K, Cu, Mg, Mn, Na, Ni, Se, V and Zn
- 13.040.20
- VDI 2465 BLATT 2 Measurement of soot (Ambient Air) - Thermographical determination of elemental carbon after thermal desorption of organic carbon
- VDI 2465 BLATT 2 Measurement of soot (Ambient Air) - Thermographical determination of elemental carbon after thermal desorption of organic carbon
- VDI 2465 BLATT 2 Measurement of soot (Ambient Air) - Thermographical determination of elemental carbon after thermal desorption of organic carbon
- Картотека зарубежных и международных стандартов
Deutsches Institut fur Normung e. V.
Ambient air - Standard gravimetric measurement method for the determination of the PM10 or PM2,5 mass concentration of suspended particulate matter; German version :2014
N EN 12341
Annotation
This European Standard describes a standard method for determining the PM10 or PM2,5 mass concentrations of suspended particulate matter in ambient air by sampling the particulate matter on filters and weighing them by means of a balance.
Measurements are performed with samplers with inlet designs as specified in Annex A, operating at a nominal flow rate of 2,3 m3/h, over a nominal sampling period of 24 h. Measurement results are expressed in g/m3, where the volume of air is the volume at ambient conditions near the inlet at the time of sampling.
The range of application of this European Standard is from approximately 1 g/m3 (i.e. the limit of detection of the standard measurement method expressed as its uncertainty) up to 150 g/m3 for PM10 and 120 g/m3 for PM2,5.
NOTE 1 Although the European Standard is not validated for higher concentrations, its range of application could well be extended to ambient air concentrations up to circa 200 g/m3 when using suitable filter materials (see 5.1.4).
This European Standard describes procedures and gives requirements for the use of so-called sequential samplers, equipped with a filter changer, suitable for extended stand-alone operation. Sequential samplers are commonly used throughout the European Union for the measurement of concentrations in ambient air of PM10 or PM2,5. However, this European Standard does not exclude the use of single-filter samplers.
This European Standard does not give procedures for the demonstration of equivalence of other sampler types, e.g. equipped with a different aerosol classifier and/or operating at different flow rates. Such procedures and requirements are given in detail in the Guide to the Demonstration of Equivalence of Ambient Air Monitoring Methods [11] and for automated continuous PM monitors (see CEN/TS 16450:2013).



